GA9050A-1 SERIES ON/OFF SAFETy
VALVE/PILOT KIT ASSEMBLY
Natural Gas Installation
1. Thread the gas control valve onto the
burner inlet fitting (see Figure 7). Use
thread sealant on the male threads of the
burner inlet fitting. Hold the burner inlet
fitting with a wrench to prevent overtight
-
ening the connection to the burner. Make
sure the control rod is facing the front (see
Figure 7).
Burner Inlet Fitting
(containing orifice)
Gas Control
Valve
Burner
Pan
Assembly
Figure 7 - Installing Gas Control Valve
Control
Rod
Figure 8 - Gas Control Valve with
Thermocouple and Pilot
Thermocouple
and Line
Pilot and
Line
Gas Control Valve
Pilot Flow
Adjustment
Screw
Figure 9 - Installing Inlet Fitting and Gas
Connector Tube
Gas Control Valve
Gas Inlet
Fitting
Gas
Connector
Tube
Inlet Opening
3. Check all joints from gas meter for natu
-
ral gas (Figure 5) or propane/LP supply
(Figure 6) to equipment shutoff valve.
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
2. Attach the pilot gas line to the pilot outlet
of the gas control valve and tighten. Con
-
nect the thermocouple to the rear of the
gas control valve. See Figure 8. Do not
overtighten. If using propane/LP gas, see
Changing Pilot Orifice
, page 6.
3. Install the inlet fitting into the inlet open
-
ing of the gas control valve (see Figure
9). Use thread sealant on the male pipe
threads.
4. Place the burner pan assembly in the
center of the fireplace floor. Make sure
the front of pan faces forward.