background image

www.fmiproducts.com

124379-01A

6

FIREPLACE INSTALLATION

FRAMING

1.  Frame opening for fireplace using dimen

-

sions shown in Figures 4 and 5.

2.  If  fireplace  is  to  be  installed  directly  on 

carpeting, tile (other than ceramic) or any 

combustible  material  other  than  wood 

flooring, fireplace must be installed upon 

a metal or wood panel extending full width 

and depth of fireplace.

3.  Set fireplace directly in front of this open

-

ing and slide unit back until nailing flanges 

touch side framing.

4.  Check level of the fireplace and shim with 

sheet metal if necessary.

5.  Before  securing  fireplace  to  prepared 

framing, ember protector (provided) must 

be placed between hearth extension (not 

supplied) and under bottom front edge of 

fireplace to protect against glowing embers 

falling through. If fireplace is to be installed 

on a raised platform, a Z-type ember pro

-

tector (not supplied) must be fabricated to 

fit  your  required  platform  height.  Ember 

protector should extend under fireplace a 

minimum of 1 

1

/

2

". Ember protector should 

be  made  of  galvanized  sheet  metal  (28 

gauge minimum to prevent corrosion.

6.  Using screws or nails, secure fireplace to 

framing through flanges located on sides 

of fireplace.

30.125"

59" (50" Models)

58.125"

67.125"

51.25" (42" Models)

45.25" (36" Models)

28.250" (36" Models)

Figure 4 - Framing Dimensions

71" (50" Models)

100" (50" Models)

65" (42" Models)

92" (42" Models)

86.5" (36" Models)

61" (36" Models)

Maintain 1 

1

/

2

"

Clearance 

at Sides and 

Back of Fireplace

1

/

2

" Clearance

Not Required at 

Nailing Flanges 

Figure 5 - Corner Installation

SELECTING LOCATION

To  determine  the  safest  and  most  efficient 

location for the fireplace, you must take into 

consideration the following guidelines:
1.  The location must allow for proper clear

-

ances (see Figures 4 and 5).

2.  Consider a location where fireplace will 

not be affected by drafts, air conditioning 

ducts, windows or doors.

3.  A location that avoids cutting of joists or 

roof rafters will make installation easier.

4.  An  outside  air  kit  is  available  with  this 

fireplace (see 

Optional Outside Air Kit

 on 

page 8).

MINIMUM CLEARANCE TO 

COMBUSTIBLES

Back and sides of fireplace 

1

/

2

" min.*

Front of fireplace 

48" min.

Floor** 

0" min.

Perpendicular wall to opening 

18" min.

     36" Models 

12" min.

Top spacers 

0" min.

Mantel clearances 

see 

Mantels

, page 7

Chimney outer pipe surface 

2" min.

     36" Model 

1" min.

 

* Not required at nailing flanges
** See step 2 of 

Framing

 WARNING: Do not pack re

-

quired air spaces with insulation 

or other materials.

Minimum/Maximum Chimney Height for 

Residential Installation

Minimum height of chimney, measured from 

base of fireplace to flue gas outlet of termina

-

tion, is 16 feet for straight flue or a flue with 

one elbow set. Maximum distance between 

elbows is 6 feet. For systems with two elbow 

sets,  minimum  height  is  22  feet.  Maximum 

height of any system is 50 feet. This measure

-

ment includes fireplace, chimney sections and 

height of termination assembly at level of the 

flue gas outlet (see Figure 15, page 11).

Minimum/Maximum Chimney Height for 

Outdoor Installation

Minimum height of chimney, measured from 

base of fireplace to flue gas outlet of termina

-

tion, is 9.5 feet (minimum of 4 feet of chimney 

pipe sections required for outdoor installation).

Summary of Contents for G36A Series

Page 1: ...with a vent free gas log heater approved to ANS Z21 11 2 standard This wood burning fireplace complies with UL127 CAN ULC S610 M87 standard as a FACTORY BUILT FIREPLACES FOR CANADA The authority havi...

Page 2: ...cation in fireplace and refer to fire log warnings and caution markings on packaging prior to use Thisfireplaceisnotintendedtobe used as a substitute for a furnace to heat an entire home Use for suppl...

Page 3: ...S 12 EACH SIDE COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE MINIMUM 12 TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 74 X 20 1 CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL OUTSIDE AIR 36...

Page 4: ...GAS LINE KNOCKOUTS 12 EACH SIDE COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE MINIMUM 18 TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 66 X 20 2 CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIA...

Page 5: ...OMBUSTIBLE MATERIAL COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE 0 TO BOTTOM OUTSIDE AIR 11 2 AIR SPACE BACK AND SIDES GAS LINE KNOCKOUTS 12 EACH SIDE MINIMUM 18 TO PERPENDICULAR SIDEWALL HE...

Page 6: ...nges Figure 5 Corner Installation SELECTING LOCATION To determine the safest and most efficient location for the fireplace you must take into consideration the following guidelines 1 The location must...

Page 7: ...bustible material see Figure 6 WARNING Hearthextension is to be installed only as shown in Figure 6 FIREPLACE INSTALLATION Continued Figure 6 Hearth Extension Seal Gap Fireplace Front Ember Protector...

Page 8: ...ns Figure 8 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inl...

Page 9: ...ipe sections are locked to gether When installing double wall snap lock chimney together it is important to assure the joint between the chimney sections is locked Check by pulling chimney upward afte...

Page 10: ...igure 14 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a 1 36...

Page 11: ...tom Overlap Shingles Top and Sides Only Figure 16 Flashing Installation FLASHING INSTALLATION V6F 10DM OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pi...

Page 12: ...2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 20 10 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In any c...

Page 13: ...y should be postioned a distance apart as shown in Figure 21 4 Install rear refractory panel This panel has a top and bottom To determine which is which match up the pattern on the rear panel with the...

Page 14: ...la tion from gas line conduit sleeve Save insulation for reuse Replace screws 3 Run a 1 2 black iron gas line into fireplace through the rear at gas line conduit sleeve if usingaraisedplatform addheig...

Page 15: ...ce must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces ANS Z21 60 or Z21 84 and shall also be installed in accordance with the National Fuel Ga...

Page 16: ...Installing Bi Fold Doors Spring Clip Insert Pin into Spring Clip Pivot Hole Insert Bottom Pivot Pin into Hole Fold Door and Slide Top Pins Into Track Figure 29 Adjusting Bi Fold Doors INSTALLING GLAS...

Page 17: ...and a gradual temperature rise to 550 F which is more than a normal fire will generate Such materials as pitch wax laden logs very dry mill end lumber and large amounts of paper or cardboard boxes can...

Page 18: ...www fmiproducts com 124379 01A 18 PARTS MODELS V G36 42 50 SERIES AND V J36 42 50 SERIES 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4...

Page 19: ...e 2 15 21171 Gas Conduit Cover 4 16 109752 01 Conduit One 2 17 109752 02 Conduit Two 2 18 Heat Shield Support 1 19 123298 02 Ash Box Assembly 1 20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Con...

Page 20: ...www fmiproducts com 124379 01A 20 PARTS MODELS MODELS V G36 42 50 SERIES AND V J36 42 50 SERIES Picture may vary from actual 1 2 5 3 4 6 6...

Page 21: ...1 125841 02 Right Herringbone 50 Red 1 3 116081 02 Left Stacked 36 Red 1 116086 02 Left Herringbone 36 Red 1 125833 02 Left Stacked 42 Red 1 125836 02 Left Herringbone 42 Red 1 125839 02 Left Stacked...

Page 22: ...116081 01 Left Stacked 36 Natural White 1 116086 01 Left Herringbone 36 Natural White 1 125833 01 Left Stacked 42 Natural White 1 125836 01 Left Herringbone 42 Natural White 1 125839 01 Left Stacked 5...

Page 23: ...tion or troubleshooting If so contact FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and se rial numbers of your fireplace ready You can also visit our web site at www fmiprodu...

Page 24: ...FLASHING V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM COLLAR...

Reviews: