PRE-INSTALLATION
PREPARATION
Continued
Figure 6 - Framing Clearances for Corner Installation
These models are approved for use with
FMI 7" direct-vent pipe components and
terminations.
Your fireplace is approved to be vented either
through the side wall, or vertically using the
following guidelines:
• Only use FMI venting components or kits
specifically approved for this fireplace.
• Minimum clearance between vent pipes
and combustible materials is 1" (25 mm),
except where stated otherwise.
• Combustible material may be flush with
the top front of fireplace with a maxi-
mum thickness of 3/4".
• Do not recess venting terminals into a
wall or siding.
• If exterior wall is vinyl, you must use a
vinyl siding standoff.
• Install horizontal venting with a 1/4" rise
for every 12" of run toward the termination.
• You may paint the vent terminal with
450ºF (232ºC) heat-resistant paint to co-
ordinate with the exterior finish.
• There must not be any obstruction such
as bushes, garden sheds, fences, decks,
or utility buildings within 24" from the
front of the termination cap.
• Do not locate termination cap where ex-
cessive snow or ice build up may occur.
Be sure to clear vent termination area af-
ter snow falls to prevent accidental block-
age of venting system. When using snow
blowers, do not direct snow towards vent
termination area.
Location of Vent Termination
When locating vent termination, it is impor-
tant to observe the minimum clearances
shown in Figure 8, page 6. You will avoid
extra framing by positioning your fireplace
against an already existing framing mem-
ber. The sides of the fireplace may be posi-
tioned directly against combustible walls.
*Check with local codes or with the current
CAN/CGA B149 [.1 or .2] Installation Codes
for Canada or the USA Installations follow
the current National Fuel Gas Code, ANS
Z223.1, also known as NFPA 54.
GENERAL VENTING
C
B
A
D
E
F
G
Top of Louver Opening
3
2
1
4
5
6
7
Wall
Figure 7 - Clearances for Combustible Mantels
Ref.
Mantel Depth
Ref. Mantel from Top
of Louver Opening
1
14" (356mm)
A
16" (406mm)
2
12" (305mm)
B
14" (356mm)
3
10" (254mm)
C
12" (305mm)
4
8" (203mm)
D
10" (254mm)
5
6" (152mm)
E
8" (203mm)
6
4" (101mm)
F
6" (152mm)
7
2" (51mm)
G
4" (101mm)
Continued
Note: There must be
a minimum clear-
ance of 18" above
top of louver
opening when
installing a television
or entertainment
center above the
fireplace.