www.fmiproducts.com
125206-01B
24
FIREPLACE INSTALLATION
Continued
OPTIONAL WIRELESS HAND-HELD
REMOTE CONTROL INSTALLATION
Note: If using an optional wireless hand-
held remote control, wall switch is no longer
operational.
INSTALLING OPTIONAL WIRELESS
HAND-HELD REMOTE CONTROL
MRC SERIES
NOTICE: Use only alkaline bat
-
teries (not included).
Installing Remote Receiver
1. Open bottom louver and locate switch
bracket on the right.
2. Remote receiver can be placed in the hole
on the switch bracket or placed on the
floor underneath the firebox, see Figure
37. See remote instructions for further
information.
3. Attach terminal wires to battery.
4. Connect wires from receiver to TH and
TPTH to control valve (see Figure 38).
GAS LINE HOOK-UP
WARNING: Before you pro
-
ceed, make sure your gas supply
is OFF.
WARNING: Gas line hookup
should be done by your gas
supplier or a qualified service
person.
An equipment shutoff valve has been included
in the appliance’s gas supply system. You may
consider installing an extra gas shutoff valve
outside appliance’s enclosure (check with
local codes) where it can be accessed more
conveniently with a key through a wall (see
Figure 39, page 25).
Route a 1/2" NPT black iron gas line towards
appliance coming in from the left. It is rec-
ommended to route pipe between stand of
firebox and surround of fireplace (see Figure
40, page 25).
IMPORTANT:
The appliance and its individual
shutoff valve must be disconnected from the
gas supply piping system during any pressure
testing of 1/2 psig. (3.5 kPa). The appliance
must be isolated from the gas supply piping
system by closing its individual equipment
shutoff valve during any pressure testing of
the gas supply piping system at test pressure
equal to or less than 1/2 psig. (3.5 kPa).
Figure 37 - Remote Receiver
Figure 38 - Control Valve Terminals
To Optional
Remote
Accessory
To Wall
Thermostat
Wire terminals
Remote Receiver
Receiver
Slide
Button
REMOTE
OFF
ON
LEARN
ADJ.
f i r e - p a r t s . c o m