FIREPLACE INSTALLATION
CAUTION: Due to high tem
-
peratures, make sure wires are
not touching upper firebox.
Figure 35 - Removing Louver
Glass
Locating
Holes
Spring
Latch
Figure 34 - Wall Switch Wiring Diagram,
Millivolt Units
Note: If any of the original wire supplied must
be replaced, use type 18 AWG-105° C (25 feet
length maximum) or equivalent.
OFF
P
IL
O
T
ON
LO
HI
PI
LOT
E
A
16AI
7
TPTH
TP
TH
Wall Switch
Route Millivolt Wires
Through Gas Line
Conduit Sleeve
To
Thermopile
(Back
View)
ELECTRICAL HOOKUP FOR
OPTIONAL BLOWER ACCESSORY
Before blower accessory can be operated,
appliance outlet box must be properly con-
nected to a standard 120 VAC power source.
This must be done when appliance is origi-
nally installed. Refer to
Wiring Diagram
on
page 33.
An outlet box with two receptacles has been
supplied for your convenience and is located
on the lower right side of appliance (see
Figure 36). The variable speed controller is
mounted on a magnetic base and may be
positioned anywhere within an accessible
distance behind louvered opening (see
Figure 35).
You may test blower for operation by turning
control knob clockwise just until it clicks on
which is the full on position. Adjust fan speed
to lowest setting (this should be no more than
1/4 of a turn clockwise).
Recommended
Blower Speed
Control Location
OFF
P
IL
O
T
ON
LO
HI
PI
LOT
E
A
16AI
7
TPTH
TP
TH
WALL SWITCH INSTALLATION
The DVF32TMHPN/TMHST models use a self
generated millivolt current that allows you to
activate the gas control valve directly without
the use of normal household electricity (see
Figure 34). Both versions are supplied with
a wall switch kit for ready connection and
mounting.
1. To remove louvers, simultaneously pull
both top end spring latches towards center
of appliance until they are disengaged
from locating holes. Repeat for bottom
spring latches and pull louvers outward.
Reverse procedure to install louvers back
onto appliance (see Figure 35).
2. Connect 18 gauge wires from wall switch
to gas control valve terminals marked
TH and TPTH or to ignition module using
pigtails and wire nut connectors supplied
with appliance.
Figure 36 - Connecting Blower
Accessory to Power Supply
For Optional
Fan Kit
From Blower
Assembly
f i r e - p a r t s . c o m