www.fmiproducts.com
119315-01D
25
ClEaNiNG aND MaiNTENaNCE
Continued
TRoUBlEshooTiNG
WARNING: Turn off and unplug fireplace and let cool before
servicing. Only a qualified service person should service and repair
fireplace.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note:
All troubleshooting items are listed in order of operation.
POSSIbLE CAUSE
1. Ignitor electrode not con-
nected to ignitor cable
2. Ignitor cable pinched or
wet
3. Broken ignitor cable
4. Bad ignitor
5. Ignitor electrode posi-
tioned wrong
6. Ignitor electrode broken
7. Battery not installed, bat
-
tery power low or battery
not installed correctly
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched
by any metal or tubing.
Keep ignitor cable dry
3. Replace ignitor cable
4. Replace ignitor
5. Replace pilot assembly
6. Replace pilot assembly
7. Install new alkaline battery
in electronic ignitor. Verify
battery is installed cor-
rectly
ObSERVED PRObLEM
When ignitor button is pressed,
there is no spark at ODS/pi-
lot
LOG SET
• If you remove one-piece log set for clean
-
ing, refer to
Installing Log Set and Screen
,
page 18, for placement instructions.
• Replace log set if broken or chipped (dime-
sized or larger).
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to remove
dust.