www.fmiproducts.com
119315-01D
20
opERaTiNG FiREplaCE
Continued
9. To turn off burner and leave pilot lit:
Turn control knob clockwise
to
the PILOT position.
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to
the OFF position.
2. Close equipment shutoff valve (see
Figure 16, page 15)
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under
Light-
ing Instructions
, page 19.
2. With control knob pressed in, strike
match. Hold match to pilot until pilot
lights.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 under
Lighting Instruc-
tions
, page 19.
REMoTE-REaDy MoDEls
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per
-
sonal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the pi
-
lot, follow these instructions exactly.
b. bEFORE LIGHTING smell all around
the appliance area for gas. be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don’t try to repair it, call a quali
-
fied service technician or gas supplier.
Force or attempted repair may result in
a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
LIGHTING
INSTRUCTIONS
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire
-
place screen is installed before
running fireplace.
NOTICE: During initial operation
of new fireplace, burning logs will
give off a paper-burning smell.
Open window to vent smell. This
will only last a few hours.
WARNING: Burner will come
on automatically within one min-
ute when control valve is in the
ON position after the pilot is lit.
1. STOP! Read the safety information in
column 1.
2. Make sure equipment shutoff valve is
fully open.
3. Press in and turn control knob clock
-
wise
to the OFF position (see
Figure 26).
Figure 26 - Control Knob and Ignitor
Button Location (Shown as Supplied -
No Control Options)
Control Knob
Electronic Ignitor