www.fmiproducts.com
107826-01L
6
Mantels or any other combustible material
may come up to side edge of black metal face
of fireplace if projection from front face falls
within limits shown in Figure 6.
Fireplace insTallaTion
Continued
12
1
/
4
" Ref.
6"
Ref.
15" Min.
12" Min.
1
1
/
2
" Max.
3" Nom.
33°
Combustible
Material
Safe
Zone for
Projection of
Combustible
Materials
Fireplace Opening
Upper
Section of
Fireplace
Figure 4 - Mantel Clearances to
Combustible Material (with Louver)
Electrical
Bushing
Electrical
Cover
Plate
Rocker
Switch
Figure 7 - Fan Switch-Electrical Bushing
Electrical
Housing
Wire Nut (3x)
(Not Supplied)
Outer Wrapper
of Fireplace
Electrical Cover
Plate and
Electrical Bushing
Fireplace Chassis
Ground
To Power
Source
Receptacle
(Supplied)
Power Source Wiring
(Not Supplied)
Prewired Receptacle
and Ground
MANTELS
A mantel may be installed if desired (see
Figures 4 and 5). Woodwork such as wood
trims, mantels or any other combustible ma
-
terial projecting from front face, must not be
placed within 12" of fireplace opening and
within 9" of top louver opening. Combustible
materials above 12" and projecting more than
1
1
/
2
" from fireplace must not be placed less
than 12" from top opening of fireplace (NFPA
STD 211, Sec. 7-3.3.3).
Figure 5 - Mantel Clearances to
Combustible Material (without Louver)
12
1
/
4
" Ref.
1
1
/
2
"
Max.
Upper Section
of Circulating
Fireplace
6"
Ref.
9"
Min.
33°
3" Nom.
*Note
: Drawing
Not To Scale
Safe Zone For
Projection of
Combustible
Materials
Combustible
Material
15"
Min.
12"
Min.
Fireplace Opening
Top of
Louvered
Opening
FAN/BLOWER KIT ASSEMBLY
Fan or blower kit is optional with this fireplace
(circulating models only). Use of blowers or
fans other than those manufactured by FMI
PRODUCTS, LLC voids warranty. Fan is op
-
erated by pressing rocker switch (see Figure
7) in lower right hand corner of fireplace face.
Blower is operated by turning control knob
(not shown).
Fan/blower kit electrical connections are
made through electrical cover plate on side
of fireplace a shown in Figure 7.
FIREBOX
SAFE ZONE
Figure 6 - Side Mantel Clearance
Top View of Fireplace
Min. 12" from
Perpendicular Side Wall
3"
2" Max.
33°
8"
Sheet
Metal
Screws