background image

RVP-412 MOUNTING INSTRUCTIONS (cont.) 
 
 

Select one of the un-used nine positions in the RMS-400 to be 

occupied by the new RVP-412 circuit board module. Remove the blank 
label in that position by peeling it off of the front panel. Peel 
the label slowly to remove all of the label and adhesive. Any 
remaining adhesive may be removed by rubbing the surface with your 
thumb. WARNING: DO NOT USE SOLVENTS TO REMOVE THE LABEL ADHESIVE. 
The solvent could damage the equipment cards or cause a fire. 
 
 

Peel the backing off of the new label and apply it to the 

 

front panel of the RMS-400 rack in the position of the new 

card. Align the new label with the screw head in the hole in the 
lower right hand corner of the label then align the center 
thumbscrew hole with the clearance hole in the front panel. This 
should cause the label to be straight and vertical. When the label 
is in place press firmly to secure the label.  
 
 

Then remove the thumb-screw retainer from the RVP-412, it is 

located at the front of the card and is removed by rotating the 
knob counter-clock-wise. 
 
 

Next slide the card into the card guides at the rear of the 

RMS-400. Be sure that the notch in the circuit card is facing 
forward and down. Push the card all the way to the front of the 
rack until it stops. DO NOT APPLY EXCESSIVE FORCE TO THE CARD. 
 
 

Insert the thumb-screw that was previously removed while 

rotating it in a clock-wise direction. When it begins to thread 
into the card, continue until it is finger tight. CAUTION TIGHT BY 
HAND ONLY, DO NOT USE TOOLS TO TIGHTEN THE THUMB-SCREW. OVER 
TIGHTENING WILL DAMAGE THE CIRCUIT CARD. 
 
 
CAUTION: 
Most circuit board modules have several adjustments which are 
 

carefully factory set with precision instruments for optimum 

performance. Change only those which must be adjusted, some 
controls when mis-adjusted produce little change under normal 
 

operating conditions, but can seriously reduce the ability of 

the unit to function correctly under other conditions which may be 
 

encountered. Therefore, if you must adjust a control, place a 

mark on it before moving it, so that it may be returned to its 
original setting with reasonable accuracy. 
 
HOW TO CABLE THE TVP-20 
 
Connect the video cable you wish to use to the "CAMERA A INPUT" 
BNC connector and connect the cable going to the RVP-20 to the 
"CABLE OUTPUT" BNC connector. It is not necessary for power to be 
on at this time, the video path will only be interrupted during 
the cable attachment. Next connect the Second camera video output 
to the "CAMERA B INPUT". BE SURE TO TERMINATE THE END OF THE VIDEO 
CABLE WITH A 75 OHM TERMINATION OR PROPERLY TERMINATE INTO OTHER 
EQUIPMENT.  
 
 
 
 
RVP-412.ISB 

      PAGE 

OF 

Summary of Contents for RVP-412

Page 1: ...TVP 20 RVP 412 CCTV VIDEO PLEXER INSTRUCTION BOOK IB640701 4 1 2003 ...

Page 2: ...3 RVP 412 MOUNTING INSTRUCTIONS 3 4 HOW TO CABLE THE TVP 20 5 HOW TO CABLE THE RVP 20 5 POWER SUPPLY INSTALLATION 5 OPERATION 5 CARE AND MAINTENANCE 5 APPLICATIONS WHERE TO USE THE SYSTEM 5 APPLICATIONS LONG DISTANCE VIDEO ON COAX 6 RVP 412 ISB PAGE 1 OF 4 ...

Page 3: ... ready to go The system is housed in a black ABS enclosure that has a UL flame rating of 94 VO and is powered by any 24VAC power transformers The system has an LED power indicator light to help installation The RVP 412 is a slide in rack mounted card that is identical in operation to the RVP 20 The rack mounted card version mounts into the RMS 400 mainframe and power supply MOUNTING INSTRUCTIONS T...

Page 4: ...to the front of the rack until it stops DO NOT APPLY EXCESSIVE FORCE TO THE CARD Insert the thumb screw that was previously removed while rotating it in a clock wise direction When it begins to thread into the card continue until it is finger tight CAUTION TIGHT BY HAND ONLY DO NOT USE TOOLS TO TIGHTEN THE THUMB SCREW OVER TIGHTENING WILL DAMAGE THE CIRCUIT CARD CAUTION Most circuit board modules ...

Page 5: ...the other One transmitter and one receiver is required to complete the system CARE AND MAINTENANCE There is no routine maintenance or calibration required with this equipment There are no field adjustable controls inside the box Opening the box will void your warranty APPLICATIONS WHERE TO USE THE SYSTEM This system can be used anywhere that a video signal in coax cable exists Some uses are in a C...

Reviews: