RVP-412 MOUNTING INSTRUCTIONS (cont.)
Select one of the un-used nine positions in the RMS-400 to be
occupied by the new RVP-412 circuit board module. Remove the blank
label in that position by peeling it off of the front panel. Peel
the label slowly to remove all of the label and adhesive. Any
remaining adhesive may be removed by rubbing the surface with your
thumb. WARNING: DO NOT USE SOLVENTS TO REMOVE THE LABEL ADHESIVE.
The solvent could damage the equipment cards or cause a fire.
Peel the backing off of the new label and apply it to the
front panel of the RMS-400 rack in the position of the new
card. Align the new label with the screw head in the hole in the
lower right hand corner of the label then align the center
thumbscrew hole with the clearance hole in the front panel. This
should cause the label to be straight and vertical. When the label
is in place press firmly to secure the label.
Then remove the thumb-screw retainer from the RVP-412, it is
located at the front of the card and is removed by rotating the
knob counter-clock-wise.
Next slide the card into the card guides at the rear of the
RMS-400. Be sure that the notch in the circuit card is facing
forward and down. Push the card all the way to the front of the
rack until it stops. DO NOT APPLY EXCESSIVE FORCE TO THE CARD.
Insert the thumb-screw that was previously removed while
rotating it in a clock-wise direction. When it begins to thread
into the card, continue until it is finger tight. CAUTION TIGHT BY
HAND ONLY, DO NOT USE TOOLS TO TIGHTEN THE THUMB-SCREW. OVER
TIGHTENING WILL DAMAGE THE CIRCUIT CARD.
CAUTION:
Most circuit board modules have several adjustments which are
carefully factory set with precision instruments for optimum
performance. Change only those which must be adjusted, some
controls when mis-adjusted produce little change under normal
operating conditions, but can seriously reduce the ability of
the unit to function correctly under other conditions which may be
encountered. Therefore, if you must adjust a control, place a
mark on it before moving it, so that it may be returned to its
original setting with reasonable accuracy.
HOW TO CABLE THE TVP-20
Connect the video cable you wish to use to the "CAMERA A INPUT"
BNC connector and connect the cable going to the RVP-20 to the
"CABLE OUTPUT" BNC connector. It is not necessary for power to be
on at this time, the video path will only be interrupted during
the cable attachment. Next connect the Second camera video output
to the "CAMERA B INPUT". BE SURE TO TERMINATE THE END OF THE VIDEO
CABLE WITH A 75 OHM TERMINATION OR PROPERLY TERMINATE INTO OTHER
EQUIPMENT.
RVP-412.ISB
PAGE
3
OF
4