FM4040 Installation Instructions
CI 202 Iss 1 26-11-02 Page 5 of 20
INTERFACE CONNECTIONS
Relay outputs
Are clean change over contacts. The designations show the relay when
energised.
(The default state is de-energised and may be inverted with program option 64)
Arming Outputs
These voltage outputs can be used to arm the main control panel using a wireless
4173 remote control or 4180 wireless keypad.
The polarity is +12v going to 0v when armed.
They can be inverted with Program option 65
Fault outputs
These voltage outputs are for connection to a communicator.
Supervisory operates if a wireless detector supervisory signal fails to be received.
Low battery operates if a low battery transmission is received from a wireless
detector
Jamming operates if an interfering radio transmission is present which may
interfere with the correct operation of the wireless system.
The polarity is +12v going to 0v when jammed.
The output can be inverted with Program option 65