FM4040 Installation Instructions
CI 202 Iss 1 26-11-02 Page 18 of 20
APPENDIX B PROGRAM OPTIONS (NOT CLASS 6)
These program options are for other applications.
For Class 6 alarm systems they should all be set to the Factory default.
61 ZONE 1 TO 8 RELAY OPERATION MODE
The relays either operate all the time or only when the arming input is active.
i.e. If you have Part & Full set inputs connected to your wired panel, you can then
choose which zones are active in Part Set & which zones are active in Full Set.
0 = All the time
1 = Only when Part or Full set input is high
Press the full set key to exit
62 FAULT OUTPUTS ALSO OPERATE THE ZONE OUTPUT
Default is 0
If set to 1 the zone and fault outputs operate together.
Do Not set to 1 when connecting to a wired panel as the zone output will indicate
that a detector has alarmed & generate a false alarm.
71 – 78 select the Zone relays 1 to 8.
Options available for the zone outputs
include NORMAL, LATCHING or TIMED
For use as a Class 6 Interface the default (1) is recommended.
71 Zone 1 operation time
72 Zone 2 operation time
73 Zone 3 operation time
74 Zone 4 operation time
75 Zone 5 operation time
76 Zone 6 operation time
77 Zone 7 operation time