background image

10

When working on the pump, observe carefully the fol-
lowing precautions:

— make sure that the pump has been drained and

properly flushed with clean water.

— rinse the various components after disassembling

them.

— observe good standards of personal hygiene.

— bear in mind the risk of infections.

— follow the local safety rules.

The pump is intended for use in liquids that may be
harmful to your health. To prevent any harm to eyes and
skin, observe the following rules when working on the
pump:

— always use protective goggles and rubber gloves.

— hold a rag over the oil casing screw  when removing it.

Otherwise, pressure that may have built up in the
pump due to leakage of liquid into the pump may
cause splatter into the eyes or onto the skin.

Follow the following procedure if harmful chemicals
come into contact:

with your eyes:

— rinse immediately with running water for 15 minutes,

keeping the eyelids wide open

— contact an oculist

with your skin:

— remove contaminated clothing

— wash the skin with soap and water

— if necessary, consult a doctor.

CARE AND MAINTENANCE

— Make sure that the machine (or

parts of the machine) can't roll
or fall over and injure people or
damage property.

— Check that the power supply is

disconnected and that the pump
cannot start up again, not even
accidentally, before commencing
any work on it.

This also applies to the control
circuit.

NOTE! Flygt does not assume any liability in the event
of such work being done by unauthorised persons.

Inspection

Periodic checks and preventive maintenance mean
more reliable operation over time.

The pump should be inspected at least once a year if it
runs intermittently, andat the intervals indicated below
if it runs continuously in conditions of normal difficulty.

If the conditions are particularly demanding, intensify
the number of inspections.

Interval between inspections and overhaul.

For details regarding service and inspection check
appropriate pump Installation, care and maintainence
manual.

Jet aerator

Oil inspect.

General

hours

overhaul

JA-112-S/P5-3085-460

4000

1-2 year

JA-112-S/P5-3102-460

4000

1-2 year

JA-117-S/P5-3127-437

4000

1-2 year

JA-117-S/P5-3153-432

8000

1-2 year

JA-117-S/P5-3171-433

8000

 2-3 year

JA-217-S/P5-3202-434

8000

 2-3 year

JA-317-S/P5-3202-610

8000

 2-3 year

JA-417-S/P5-3301-620

8000

 2-3 year

JA-112-S/P6-3085-462

4000

1-2 year

JA-112-S/P6-3102-463

4000

1-2 year

JA-117-S/P6-3127-438

4000

1-2 year

JA-117-S/P6-3153-435

8000

 2-3 year

JA-117-S/P6-3171-435

8000

 2-3 year

JA-217-S/P6-3202-641

8000

 2-3 year

JA-317-S/P6-3202-614

8000

 2-3 year

JA-417-S/P6-3301-624

8000

 2-3 year

 P- or S-installation

These overhauls require special tools and should be
done in a Flygt workshop.

When the pump is new or the seals have been re-
placed, an inspection after the first week of operation is
recommended.

IMPORTANT!  Periodic inspection of the handle and
the fixing elements between the pump and the pipes is
very important.

Summary of Contents for JA-112-P5-3085-460

Page 1: ...1 Installation care and maintenance Jet aerator 894263 04...

Page 2: ...instructions in this manual which could cause danger to life if not observed have been specifically highlighted with this general dangersymbol Identification of safety and warning symbols SAFETY High...

Page 3: ...be kept for 15 years after the manufacture of this product has beendiscontinued The manufacturer reserves the right to alter perfor mance specification or design without notice Only Ex approved pumps...

Page 4: ...55 620 4817 4 95 JA 112 S P6 3085 462 S P 60 3085 MT 2 2 462 4812 1 55 JA 112 S P6 3102 463 S P 60 3102 MT 3 7 463 4812 1 55 JA 117 S P6 3127 438 S P 60 3127 MT 7 5 438 4817 1 95 JA 117 S P6 3153 435...

Page 5: ...f the pump For pump type see page 2 Inlet and delivery pipes hot dip galvanised carbon steel or stainless steel Ejector body stainless steel cast iron Nozzle PE Diffuser pipe stainless steel AISI304 S...

Page 6: ...ll or fall over flame to thaw the pump The pump must be run for a short period after being taken up in order to expel all remainingwater For longer periods of storage the pump must be pro tected again...

Page 7: ...ment must be suitable for extracting the pump and lowering it into the sump without having to repeat the operation Overdimensionedhandlingequipmentmightcause damage to the unit Make sure that the hand...

Page 8: ...ay be tied to the stainless steel rope mentioned above Make sure that cables are not bent or squeezed in such a way as to be liable to break or wear out Installation in full tank The Jet aerator unit...

Page 9: ...se two phases OPERATION Watch out for the starting jerk which be very powerful Check that the power supply is disconnected and that the pump cannot start up again not even accidentally beforecommencin...

Page 10: ...OTE Flygt does not assume any liability in the event of such work being done by unauthorised persons Inspection Periodic checks and preventive maintenance mean more reliable operation over time The pu...

Page 11: ...ude leaves Silencers are available as an alternative to end sections Basket filters to exclude leaves Made of galvanised perforated sheet steel and capable of being fitted to the upper end of the end...

Page 12: ...12 Spare parts are only available on special request JA 112 XY 3085 460 462 X S or P installation Y 50 or 60 Hz...

Page 13: ...13 Spare parts are only available on special request JA 112 XY 3085 460 462 X S or P installation Y 50 or 60 Hz...

Page 14: ...14 Spare parts are only available on special request JA 112 XY 3102 460 463 X S or P installation Y 50 Hz or 60 Hz...

Page 15: ...15 Spare parts are only available on special request JA 112 XY 3102 460 463 X S or P installation Y 50 Hz or 60 Hz...

Page 16: ...16 Spare parts are only available on special request JA 117 XY 3127 437 438 X S or P installation Y 50 or 60 Hz...

Page 17: ...17 Spare parts are only available on special request JA 117 XY 3127 437 438 X S or P installation Y 50 or 60 Hz...

Page 18: ...18 Spare parts are only available on special request JA 117 XY 3153 432 435 X S or P installation Y 50 or 60 Hz...

Page 19: ...19 Spare parts are only available on special request JA 117 XY 3153 432 435 X S or P installation Y 50 or 60 Hz...

Page 20: ...20 Spare parts are only available on special request JA 117 XY 3171 433 435 X S or P installation Y 50 or 60 Hz...

Page 21: ...21 Spare parts are only available on special request JA 117 XY 3171 433 435 X S or P installation Y 50 or 60 Hz...

Page 22: ...22 Spare parts are only available on special request JA217 XY 3202 434 641 X S or P installation Y 50 or 60 Hz...

Page 23: ...23 Spare parts are only available on special request JA217 XY 3202 434 641 X S or P installation Y 50 or 60 Hz...

Page 24: ...24 Spare parts are only available on special request JA 317 XY 3202 610 614 X S or P installation Y 50 or 60 Hz...

Page 25: ...25 Spare parts are only available on special request JA 317 XY 3202 610 614 X S or P installation Y 50 or 60 Hz...

Page 26: ...26 Spare parts are only available on special request JA 417 XY 3301 620 624 X S or P installation Y 50 or 60 Hz...

Page 27: ...27 Spare parts are only available on special request JA 417 XY 3301 620 624 X S or P installation Y 50 or 60 Hz...

Page 28: ...Jet aerator 01 04 Eng 06 05 ITT FLYGT AB 894263 www flygt com...