FLYGT JA-112-P5-3085-460 Installation, Care And Maintenance Download Page 2

2

CONTENTS

Safety ________________________

2

Guarantee

___________________________

  3

Data plate interpretation

___________

  4

Components of standard
Jet aerator unit _________________

4

Product description

________________

  5

General __________________________________  5
Technical data

____________________________

  5

Materials

_________________________________

 5

Applications ______________________________  5

Transportation and storage

________

 6

Installation ___________________

 

7

Safety precautions

_________________________

 7

Handling equipment

________________________

 7

General recommendations ___________________  7
Assembling Jet aerator units on site ___________  7
Sharpened support feet

_____________________

 8

Installation in tank _________________________  8

Operation

____________________________

 9

Before start-up

____________________________

 9

Starting jerk

______________________________

 9

Electrical connection

_______________

 9

Care and maintenance

_____________

10

Inspections

_______________________________

10

Accessories and tools

______________

11

Drawings ____________________

12

NOTE This “Installation, care and maintenance” for the Jet aerator must always be used together with the
“Installation, care and maintenance” for the pump type.

General danger:

Safety instructions in this
manual, which could cause
danger to life if not observed,
have been specifically
highlighted with this general
danger symbol.

Identification of safety and warning symbols

SAFETY

High voltage:

The presence of a dangerous
voltage is identified with this
safety symbol.

WARNING!

Non-observance to this warning
could damage the unit or affect
its function.

Pump

Ejector

Inst

Sw. P/N

Sales code 50 Hz

Sales code 60 Hz

3085 MT

JA-112

S

688 48 00

JA-112-S5-3085-460

JA-112-S6-3085-462

3102 MT

JA-112

S

688 65 00

JA-112-S5-3102-460

JA-112-S6-3102-463

3127 MT

JA-117

S

688 50 00

JA-117-S5-3127-437

JA-117-S6-3127-438

3153 MT

JA-117

S

688 47 20

JA-117-S5-3153-432

JA-117-S6-3153-435

3171 MT

JA-117

S

688 46 20

JA-117-S5-3171-433

JA-117-S6-3171-435

3202 MT

JA-217

S

688 58 20

JA-217-S5-3202-434

JA-217-S6-3202-641

3202 LT

JA-317

S

688 57 20

JA-317-S5-3202-610

JA-317-S6-3202-614

3301 MT

JA-417

S

688 56 20

JA-417-S5-3301-620

JA-417-S6-3301-624

3085 MT

JA-112

P

688 53 00

JA-112-P5-3085-460

JA-112-P6-3085-462

3102 MT

JA-112

P

688 66 00

JA-112-P5-3102-460

JA-112-P6-3102-463

3127 MT

JA-117

P

688 54 00

JA-117-P5-3127-437

JA-117-P6-3127-438

3153 MT

JA-117

P

688 59 20

JA-117-P5-3153-432

JA-117-P6-3153-435

3171 MT

JA-117

P

688 60 20

JA-117-P5-3171-433

JA-117-P6-3171-435

3202 MT

JA-217

P

688 61 20

JA-217-P5-3202-434

JA-217-P6-3202-641

3202 LT

JA-317

P

688 62 20

JA-317-P5-3202-610

JA-317-P6-3202-614

3301 LT

JA-417

P

688 51 20

JA-417-P5-3301-620

JA-417-P6-3301-624

Summary of Contents for JA-112-P5-3085-460

Page 1: ...1 Installation care and maintenance Jet aerator 894263 04...

Page 2: ...instructions in this manual which could cause danger to life if not observed have been specifically highlighted with this general dangersymbol Identification of safety and warning symbols SAFETY High...

Page 3: ...be kept for 15 years after the manufacture of this product has beendiscontinued The manufacturer reserves the right to alter perfor mance specification or design without notice Only Ex approved pumps...

Page 4: ...55 620 4817 4 95 JA 112 S P6 3085 462 S P 60 3085 MT 2 2 462 4812 1 55 JA 112 S P6 3102 463 S P 60 3102 MT 3 7 463 4812 1 55 JA 117 S P6 3127 438 S P 60 3127 MT 7 5 438 4817 1 95 JA 117 S P6 3153 435...

Page 5: ...f the pump For pump type see page 2 Inlet and delivery pipes hot dip galvanised carbon steel or stainless steel Ejector body stainless steel cast iron Nozzle PE Diffuser pipe stainless steel AISI304 S...

Page 6: ...ll or fall over flame to thaw the pump The pump must be run for a short period after being taken up in order to expel all remainingwater For longer periods of storage the pump must be pro tected again...

Page 7: ...ment must be suitable for extracting the pump and lowering it into the sump without having to repeat the operation Overdimensionedhandlingequipmentmightcause damage to the unit Make sure that the hand...

Page 8: ...ay be tied to the stainless steel rope mentioned above Make sure that cables are not bent or squeezed in such a way as to be liable to break or wear out Installation in full tank The Jet aerator unit...

Page 9: ...se two phases OPERATION Watch out for the starting jerk which be very powerful Check that the power supply is disconnected and that the pump cannot start up again not even accidentally beforecommencin...

Page 10: ...OTE Flygt does not assume any liability in the event of such work being done by unauthorised persons Inspection Periodic checks and preventive maintenance mean more reliable operation over time The pu...

Page 11: ...ude leaves Silencers are available as an alternative to end sections Basket filters to exclude leaves Made of galvanised perforated sheet steel and capable of being fitted to the upper end of the end...

Page 12: ...12 Spare parts are only available on special request JA 112 XY 3085 460 462 X S or P installation Y 50 or 60 Hz...

Page 13: ...13 Spare parts are only available on special request JA 112 XY 3085 460 462 X S or P installation Y 50 or 60 Hz...

Page 14: ...14 Spare parts are only available on special request JA 112 XY 3102 460 463 X S or P installation Y 50 Hz or 60 Hz...

Page 15: ...15 Spare parts are only available on special request JA 112 XY 3102 460 463 X S or P installation Y 50 Hz or 60 Hz...

Page 16: ...16 Spare parts are only available on special request JA 117 XY 3127 437 438 X S or P installation Y 50 or 60 Hz...

Page 17: ...17 Spare parts are only available on special request JA 117 XY 3127 437 438 X S or P installation Y 50 or 60 Hz...

Page 18: ...18 Spare parts are only available on special request JA 117 XY 3153 432 435 X S or P installation Y 50 or 60 Hz...

Page 19: ...19 Spare parts are only available on special request JA 117 XY 3153 432 435 X S or P installation Y 50 or 60 Hz...

Page 20: ...20 Spare parts are only available on special request JA 117 XY 3171 433 435 X S or P installation Y 50 or 60 Hz...

Page 21: ...21 Spare parts are only available on special request JA 117 XY 3171 433 435 X S or P installation Y 50 or 60 Hz...

Page 22: ...22 Spare parts are only available on special request JA217 XY 3202 434 641 X S or P installation Y 50 or 60 Hz...

Page 23: ...23 Spare parts are only available on special request JA217 XY 3202 434 641 X S or P installation Y 50 or 60 Hz...

Page 24: ...24 Spare parts are only available on special request JA 317 XY 3202 610 614 X S or P installation Y 50 or 60 Hz...

Page 25: ...25 Spare parts are only available on special request JA 317 XY 3202 610 614 X S or P installation Y 50 or 60 Hz...

Page 26: ...26 Spare parts are only available on special request JA 417 XY 3301 620 624 X S or P installation Y 50 or 60 Hz...

Page 27: ...27 Spare parts are only available on special request JA 417 XY 3301 620 624 X S or P installation Y 50 or 60 Hz...

Page 28: ...Jet aerator 01 04 Eng 06 05 ITT FLYGT AB 894263 www flygt com...

Reviews: