background image

Installing the projector- Fig. 3

 

Safety rope

The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall.
WARNING:with the exception of when the projector is positioned on the floor, the safety 

rop

e must be fitted.

This must be securely fixed to the support structure of the projector and then connected to the fixing point at 
the centre of the base.  

灯具可通过橡胶机脚放置在地板上、或安装在桁架、天花板或墙壁上。
警告:除非灯具放置在地板上,否则必须安装安全绳。
要求安全绳必须牢固地固定在灯具支架上,然后连接到底座中心固定点上。

7

Make sure all parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector.
When suspending the fixture, ensure that the supporting structure and all hardware used

 

can

 hold at least 10 times the weight of all the devices they support.

确保固定灯具的所有零部件都完好无损。
在固定灯具之前请确保固定物是牢固稳定的。
在吊装灯具时,确保支撑结构和所使用的所有配件至少可以保持

10

倍于他们支持的所有设备的重量。

Compact,standard clamp system equipped & easy installation

灯具底座配置有一体化可折叠灯钩,安装更方便,使用更安全

INSTALLATION

 

AND

 

CONNECTING/

安装与连接

Summary of Contents for Light Sky TX1940D

Page 1: ...TX1940D Please read these user manual carefully before use E mail n 43 Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China...

Page 2: ...viced correctly and safely My company disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in...

Page 3: ...eating a potential fire hazard Mounting surface and fire protection Keep all combustible materials at least 20 cm away from the fixture 20 This lighting fixture is for professional use only it is not...

Page 4: ...on optical radiation Protection against explosion The protection screen lens or ultraviolet screen on the lamp can be damaged to the degree of failure if visible damage such as a crack or deep mark sh...

Page 5: ...rol Mode DMX512 RDM ArtNet wireless DMX option 4 TECHNICAL INFORMATION Channel TX1940D Standard 1 21CH Mode 2 40CH Mode 3 93CH Mode 4 74CH Mode 5 17CH Mode 6 11CH Display The display panel adopts a 2...

Page 6: ...G B RBGW 5 Lux fc Distance m ft in 5 Diameter m ft in 55 Diameter m ft in 5 16 5 1 1 3 7 7 1 23 3 7 23 1 5 4 11 10 1 33 1 4205 391 6960 647 1720 160 22320 2074 232 22 380 36 95 9 1195 111 1122 105 184...

Page 7: ...power cord 6 425 188 506 300 436 ATTACHMENT AND BODY SIZE...

Page 8: ...support structure of the projector and then connected to the fixing point at the centre of the base 7 Make sure all parts for fixing the projector are in a good state of repair Make sure the point of...

Page 9: ...g sure all the devices had been installed with natural operate press the power switch to check whether every thing is working normally L L N Ground connection to the eiectricty mains must be carried o...

Page 10: ...9 DMX512 in signal end out in out in DMX output 1 Shield 2 Signal Signal Not connected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5...

Page 11: ...ause LED chip s brightness and wave length can not be produced exactly same by LED factory which would cause the color difference in the LED color fixture To solve the issue LIGHT SKY adopts a calibra...

Page 12: ...nd Color 17 Background Dimmer 18 Red 19 Green 20 Blue 21 White System version XY V LED KZ V DIS Board V Return ESC Channel mode Mode 1 21CH 1 21CH Mode 2 40CH 2 40CH Mode 3 93CH 3 93CH Mode 4 74CH 4 7...

Page 13: ...Speed 15 LED Effect Delay 16 Background Color 17 Background Dimmer 18 Red 19 Green 20 Blue 21 White Return ESC Reset system reset Pan Tilt reset Head motor reset Return ESC Test Test P T STEP Test ef...

Page 14: ...5 15 B 15 15 W 15 15 R 16 16 G 16 16 B 16 16 W 16 16 R 17 17 G 17 17 B 17 17 W 17 17 R 18 18 G 18 18 B 18 18 W 18 18 R 19 19 G 19 19 B 19 19 W 19 19 Return ESC Factory Defualt Time clean Developer Fir...

Page 15: ...3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow opening Slow Fast 90 119 35 3 46 7 Slow closing Slow open Slow Fast 120 179 47 1 70 2 Random strobe Slow Fast 180 249 70...

Page 16: ...ynchronous strobe slow fast 250 255 98 100 NO Function 10 0 255 Macro 11 0 255 CCT 12 0 255 StaticEffect 13 0 255 Move Effect 14 0 255 Move EffectSpeed 15 0 255 LED EffectDelay LED 16 0 255 Background...

Page 17: ...ynchronous strobe slow fast 250 255 98 100 NO Function 10 0 255 Macro 11 0 255 CCT 12 0 255 StaticEffect 13 0 255 Move Effect 14 0 255 Move Effect Speed 15 0 255 LED Effect Delay LED 16 0 255 Backgrou...

Page 18: ...Green 12 64 0 255 Blue 12 65 0 255 White 12 66 0 255 Red 13 67 0 255 Green 13 68 0 255 Blue 13 69 0 255 White 13 70 0 255 Red 14 71 0 255 Green 14 72 0 255 Blue 14 73 0 255 White 14 74 0 255 Red 15 7...

Page 19: ...97 6 Synchronous strobe slow fast 250 255 98 100 NO Function 10 0 255 Macro 11 0 255 CCT 12 0 255 StaticEffect 13 0 255 Move Effect 14 0 255 Move EffectSpeed 15 0 255 LED EffectDelay LED 16 0 255 Back...

Page 20: ...13 55 0 255 Green 13 56 0 255 Blue 13 57 0 255 Red 14 58 0 255 Green 14 59 0 255 Blue 14 60 0 255 Red 15 61 0 255 Green 15 62 0 255 Blue 15 63 0 255 Red 16 64 0 255 Green 16 65 0 255 Blue 16 66 0 255...

Page 21: ...CCT 12 0 255 StaticEffect 13 0 255 Move Effect 14 0 255 Move EffectSpeed 15 0 255 LED EffectDelay LED 16 0 255 Background Color 17 0 255 Background Dimmer Channel DMX Percentage function Note 1 DMX P...

Page 22: ...CIRCUIT CONNECTING DIAGRAM Power in Power in Motor 3 Motor 2 Motor 1 Bus Power in Power in Fan 1 Fan 2 TEM PWM PWM LED SIG 21...

Page 23: ...e down the light Please let the parts cool down 10 minute at least then begin to install 4 Please inspect the lens or other moving parts timing and keep them clear and static If find anything damaged...

Page 24: ...interrupt 3 Please check the control system is not valid check the signal amplifier of chain connected is valid 4 Please check whether the communicate cable is too long or the other equipment is mutu...

Page 25: ...24...

Reviews: