___
Attachment Brushless motor FBM 4000 Ex
13 / 28
ENGLI
SH
Risk of injury!
Only start the motor when the pump is in the liquid.
4.1
Equipotential bonding
If the motors are operated together with the pump, comprehensive, clear equipotential
bonding is essential (earthing, Fig. 1)
Fig. 1: Earthing in hazardous locations
> Connect the equipotential bonding conductor (earth wire) (1) to the designated
screw on the explosion-proof motor and pump.
> If the connection between the motor and pump already provides a conductive path
(for pumps for flammable liquids), one of the equipotential bonding conductors may
be dispensed with.
> Mains connection (2) is to be established via an explosion-proof connector, an
explosion-proof terminal box or outside of the hazardous area.
> Only use hose lines (3) with conductive hose unions (see TRbF 50 Annex B.
(R < 10
6
Ω).
> Remove paint and dirt from all connection points of equipotential bonding conduc-
tors and transition points of the containers to the electrically conductive base ground
to ensure good conductivity.
The electrically conductive base ground (4) must be an integral part of the equipotential
bonding system.
If a conductive base ground is not available, equipotential bonding conductors must be
connected to all barrels and containers.
Note!
Explosion protection at the connection point is not necessary if
the power socket or the terminal box is clearly located outside
the hazardous area.
2
3
1
4
Ω
Ω
Ω
Summary of Contents for FBM 4000 Ex
Page 8: ...___ 8 28 Anhang Bürstenloser Motor FBM 4000 Ex DEUTSCH 7 EG Baumusterprüfbescheinigung ...
Page 9: ...___ Anhang Bürstenloser Motor FBM 4000 Ex 9 28 DEUTSCH ...
Page 10: ...___ 10 28 Anhang Bürstenloser Motor FBM 4000 Ex DEUTSCH ...
Page 16: ...___ 16 28 Attachment Brushless motor FBM 4000 Ex ENGLISH 7 EC Type Examination Certificate ...
Page 17: ...___ Attachment Brushless motor FBM 4000 Ex 17 28 ENGLISH ...
Page 18: ...___ 18 28 Attachment Brushless motor FBM 4000 Ex ENGLISH ...
Page 25: ...___ Annexe moteur asynchrone FBM 4000 Ex 25 28 FRANÇAIS 7 Attestation d examen CE de type ...
Page 26: ...___ 26 28 Annexe moteur asynchrone FBM 4000 Ex FRANÇAIS ...
Page 27: ...___ Annexe moteur asynchrone FBM 4000 Ex 27 28 FRANÇAIS ...
Page 28: ...FB 98000006_04 0416 100 DEF ...