Fluke VR1710 User Manual Download Page 2

 

 

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and 
service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and 
services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of 
a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in 
Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal 
conditions of operation or handling. Fluke warrants that software will operate substantially in accordance 
with its functional specifications for 90 days and that it has been properly recorded on non-defective media. 
Fluke does not warrant that software will be error free or operate without interruption. 

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers 
only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is 
available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the 
applicable international price. Fluke reserves the right to invoice Buyer for importation costs of 
repair/replacement parts when product purchased in one country is submitted for repair in another country. 

Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, 
or replacement of a defective product which is returned to a Fluke authorized service center within the 
warranty period. 

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return 
authorization information, then send the product to that service center, with a description of the difficulty, 
postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following 
warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke 
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal 
condition of operation or handling, including overvoltage failures caused by use outside the product’s 
specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair 
costs and obtain authorization before commencing the work. Following repair, the product will be returned to 
the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges 
(FOB Shipping Point). 

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY 
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE 
FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, 
INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. 

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or 
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other 
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other 
provision. 

Fluke Corporation 
P.O. Box 9090 
Everett, WA  98206-9090 
U.S.A. 

Fluke Europe B.V. 
P.O. Box 1186 
5602 BD Eindhoven 
The Netherlands 

 

 

 

11/99 

 

To register your product online, visit 

register.fluke.com

 

Summary of Contents for VR1710

Page 1: ... VR1710 Voltage Quality Recorder Users Manual October 2007 2007 Fluke Corporation All rights reserved All product names are trademarks of their respective companies ...

Page 2: ...rvice center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caused by neglect misuse contami...

Page 3: ...Power Log 5 Loading the USB Driver 5 Setting the Time and Date 5 Connecting the Recorder for the First Time 6 Adjusting Recorder Settings with Power Log 6 Data Collection 8 Downloading and Analyzing the Data with Power Log 8 Maintenance 9 Service 9 Software Updates 9 Specifications 9 Electrical Specifications 9 General Specifications 10 Environmental and Safety Specifications 10 ...

Page 4: ...VR1710 Users Manual ii ...

Page 5: ...iii List of Tables Table Title Page 1 Symbols 3 ...

Page 6: ...VR1710 Users Manual iv ...

Page 7: ...v List of Figures Figure Title Page 1 VR1710 Voltage Quality Recorder 4 2 Power Log Drop Down List 6 3 Settings 7 ...

Page 8: ...VR1710 Users Manual vi ...

Page 9: ...rameters Recorder and Power Log features include Configurable recording interval Graphical and spreadsheet data summaries Min Max Average RMS values with time stamps Transient waveform recording Individual harmonic values and time plots Download recorded data to PC via USB cable supplied Print tables graphs and comprehensive formatted reports View print and export data Please refer to the Power Lo...

Page 10: ...he Recorder follow these guidelines Read this manual before use and follow all safety instructions Use the Recorder only as described in this User Manual or the safety features provided by the Recorder may be impaired Use only power outlet plug adapters that are supplied with the Recorder Before each use inspect the Recorder for damage Look for cracks or missing portions of it and the cables Do no...

Page 11: ...ds Conforms to relevant Canadian and US Standards CAT II This equipment is designed to protect against transients from energy consuming equipment supplied from the fixed installation such as televisions personal computers portable tools and other household appliances Lithium Battery Do not mix with the solid waste stream A qualified recycler or hazardous materials handler should dispose of spent b...

Page 12: ...f Calibration Practices The Recorder at a Glance Figure 1 shows the Recorder features 1 2 3 5 4 fbx001 eps Number Description A Recording indicator Flashing The Recorder is presently recording information Steady The Recorder has paused and is not recording information B Memory full indicator The Recorder s memory is full and needs to be downloaded before taking more readings C Power Cable D Adapte...

Page 13: ...R1710 Product CD on a PC 2 Click on VR1710 USB Driver Installation 3 Either select the default directory by clicking on Install or click Change Install Location and change the file path to a different location The necessary files are copied to the PC 4 Restart the PC to conclude driver installation Setting the Time and Date When retrieving data from the Recorder Power Log uses the PC s internal cl...

Page 14: ... the first time Windows finds the Recorder and the Windows New Hardware Wizard appears To complete installation follow these steps 1 Select the Install the software automatically Recommended option by clicking Next 2 Click Finish For the latest Recorder firmware see Firmware Updates Adjusting Recorder Settings with Power Log Before using the Recorder to collect data desired variables must be set i...

Page 15: ...rder is plugged in again The percentage of recording memory used is displayed An estimate of recording time is shown under Typical Continuous Measurement This shows the total amount of time the Recorder can collect data If transients are detected the strored waveforms will shorten the maximum recording time fbx003 bmp Figure 3 Settings Notes When choosing recording intervals note that shorter reco...

Page 16: ...ta the consumer can then send the Recorder back to the electric utility specialist The specialist can analyze the collected data with Power Log software Settings collected data and real time clock data stay intact in transit via the Recorder s non volatile memory Downloading and Analyzing the Data with Power Log To download the data from the Recorder open Power Log and click Data Download Recorder...

Page 17: ...parts Opening the case or attempting to do so will void the warranty and safety certification The USB Cable is the only replacement part in the VR1710 package If service or calibration is required please contact a local dealer or an authorized Fluke service center see Contacting Fluke Software Updates Fluke may periodically offer software and internal firmware updates for the Recorder To download ...

Page 18: ...Environmental and Safety Specifications Operating altitude 2000 m IP rating 40 indoor use only Vibration requirements Class 2 MIL PRF 28800F Drop test requirements 1 m Operating temperature 14 F to 122 F 10 C to 50 C Storage temperature 4 F to 140 F 20 ºC to 60 ºC Operating humidity without condensation 32 F to 86 F 0 C to 30 C Max 95 RH 86 F to 104 F 30 C to 40 C Max 75 RH 104 F to 122 F 40 C to ...

Reviews: