Summary of Contents for Victoreen 05-437 Operators

Page 1: ...Primalert 35 Area Radiation Monitor Operators Manual March 2005 Manual No 126011 Rev 3 2003 2005 Fluke Corporation All rights reserved Printed in U S A All product names are trademarks of their respe...

Page 2: ...Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland Ohio 44139 440 498 2564 www flukebiomedical com rms...

Page 3: ...tting Started 2 1 2 1 Receiving Inspection 2 1 2 2 Mounting 2 1 2 3 Power 2 1 2 4 Optional Power 2 2 2 5 Routine Cleaning 2 2 2 6 Attaching a Ground Wire 2 2 Section 3 Operation 3 1 3 1 Set up 3 1 3 2...

Page 4: ...Blank page...

Page 5: ...ontrol When the preset level is exceeded bright flashing red lights visible over a 1800 field and a loud intermittent signal are activated The alarms stop automatically when the radiation level falls...

Page 6: ...nds 16 mR h 200 milliseconds 32 mR h 100 milliseconds Alarms Alarm may be preset by user at any indicated discrete level by means of the front panel selector switch front panel switch selects all alar...

Page 7: ...h x 3 4 in wide x 13 in thick Unit clips to wall with removable mounting clip Accessories Supplied Appropriate 115V 230 CE approved converter P N 102007 Wall Mounting Bracket P N 74 Spare Lamp Availab...

Page 8: ...Victoreen 05 437 Operators Manual Blank page...

Page 9: ...vertical mounting surface Before mounting the bracket to the wall however make sure that the 6 ft converter power cord will reach the nearest power outlet The wall mounting bracket comes supplied with...

Page 10: ...charged cells provide approximately eight hours of operation under alarm conditions or more than 32 hours of operation The Primapak II includes a 120VAC 16VAC converter and interconnect cable 2 5 Rou...

Page 11: ...count instrument The measurement and reset time are dependent on count rate Refer to the response time specifications listed in Section 2 3 2 Testing Test the unit for proper operation by positioning...

Page 12: ...Victoreen 05 437 Operators Manual Blank page...

Page 13: ...ANSI N323 1978 Paragraphs 4 6 and 5 4 and to keep records thereof in accordance with Paragraph 4 5 of the same standard could result in erroneous readings or potential danger ANSI N323 1978 becomes by...

Page 14: ...007 Green T 1 LED 3 23 A1 710002 12 VDC Audio Alarm 1 24 U8 640001 IC 6 V Regulator 78M06 1 25 5 196 Screw PH 4 40 x 38 1 26 5 764 Washer INT 4 s CP 1 27 5 850 Nut Hex 4 40 5 CP 1 28 0911403 Screw BH...

Page 15: ...R24 185 2496 Resistor Film 2k 25W 5 1 52 R25 41 342031 Resistor Film 20k 25W 5 2 53 R21 39 303351 Resistor Film 3 3m 25W 5 2 54 R3 391052 Trim Pot 1M 5w 20 Open 1 55 R36 300501 Resistor Film 5 1 25W 5...

Page 16: ...Victoreen 05 437 Operators Manual 4 4 Figure 4 1 Primalert 35 Assembly 126028...

Page 17: ...Maintenance Maintenance 4 4 5 Figure 4 2 Primalert 35 Schematic 126015...

Page 18: ...Victoreen 05 437 Operators Manual 4 6 Figure 4 3 PC Assembly 126021...

Page 19: ......