Maintenance

Maintenance

4

 

 

4-1

Section 4 

Maintenance

 

 
4.1

 

Maintenance 

 
 

This instrument contains CMOS integrated circuits. 
No service should ever be attempted unless by a 
qualified service technician thoroughly familiar with 
these devices. Static charges normally present in a 
dry atmosphere or leakage current in soldering 
irons or other non-grounded tools can instantly 
destroy CMOS integrated devices. If this device 
has I.C. sockets, do not even attempt to remove or 
replace them. 

 
 
 
 

Failure to conduct periodic performance test in 
accordance with ANSI N323.1978, Paragraphs 4.6 
and 5.4, and to keep records thereof in accordance 
with Paragraph 4.5 of the same standard, could 
result in erroneous readings or potential danger. 
ANSI N323.1978 becomes, by this reference, a part 
of this document. 

 
An assembly drawing (Figure 4-1), schematic diagram (Figure 4-2), PC board component layout (Figure 
4-3), and applicable parts lists (Tables 4-1 and 4-2) are provided for the user's reference. 

 

Table 4-1.  Main Assembly (126028) Parts List 

Item No. 

Part No. 

Description 

Qty 

126021 

PC B Assembly 

6 126026 

Panel 

7 126027 

Case 

8 102009 

Reflector 

9 102008 

Lens 

12 500002 

SPDT 

Switch 

14 

0960008 

Parker 2-006 O-ring 

16 5-1078  Screw, 

5-20 

XI 

17 

5-99 

Screw, 1-72 x 3/16 

18 

5-26 

Screw, 4 x .25 

WARNING

WARNING

Summary of Contents for Victoreen 05-437 Operators

Page 1: ...Primalert 35 Area Radiation Monitor Operators Manual March 2005 Manual No 126011 Rev 3 2003 2005 Fluke Corporation All rights reserved Printed in U S A All product names are trademarks of their respe...

Page 2: ...Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland Ohio 44139 440 498 2564 www flukebiomedical com rms...

Page 3: ...tting Started 2 1 2 1 Receiving Inspection 2 1 2 2 Mounting 2 1 2 3 Power 2 1 2 4 Optional Power 2 2 2 5 Routine Cleaning 2 2 2 6 Attaching a Ground Wire 2 2 Section 3 Operation 3 1 3 1 Set up 3 1 3 2...

Page 4: ...Blank page...

Page 5: ...ontrol When the preset level is exceeded bright flashing red lights visible over a 1800 field and a loud intermittent signal are activated The alarms stop automatically when the radiation level falls...

Page 6: ...nds 16 mR h 200 milliseconds 32 mR h 100 milliseconds Alarms Alarm may be preset by user at any indicated discrete level by means of the front panel selector switch front panel switch selects all alar...

Page 7: ...h x 3 4 in wide x 13 in thick Unit clips to wall with removable mounting clip Accessories Supplied Appropriate 115V 230 CE approved converter P N 102007 Wall Mounting Bracket P N 74 Spare Lamp Availab...

Page 8: ...Victoreen 05 437 Operators Manual Blank page...

Page 9: ...vertical mounting surface Before mounting the bracket to the wall however make sure that the 6 ft converter power cord will reach the nearest power outlet The wall mounting bracket comes supplied with...

Page 10: ...charged cells provide approximately eight hours of operation under alarm conditions or more than 32 hours of operation The Primapak II includes a 120VAC 16VAC converter and interconnect cable 2 5 Rou...

Page 11: ...count instrument The measurement and reset time are dependent on count rate Refer to the response time specifications listed in Section 2 3 2 Testing Test the unit for proper operation by positioning...

Page 12: ...Victoreen 05 437 Operators Manual Blank page...

Page 13: ...ANSI N323 1978 Paragraphs 4 6 and 5 4 and to keep records thereof in accordance with Paragraph 4 5 of the same standard could result in erroneous readings or potential danger ANSI N323 1978 becomes by...

Page 14: ...007 Green T 1 LED 3 23 A1 710002 12 VDC Audio Alarm 1 24 U8 640001 IC 6 V Regulator 78M06 1 25 5 196 Screw PH 4 40 x 38 1 26 5 764 Washer INT 4 s CP 1 27 5 850 Nut Hex 4 40 5 CP 1 28 0911403 Screw BH...

Page 15: ...R24 185 2496 Resistor Film 2k 25W 5 1 52 R25 41 342031 Resistor Film 20k 25W 5 2 53 R21 39 303351 Resistor Film 3 3m 25W 5 2 54 R3 391052 Trim Pot 1M 5w 20 Open 1 55 R36 300501 Resistor Film 5 1 25W 5...

Page 16: ...Victoreen 05 437 Operators Manual 4 4 Figure 4 1 Primalert 35 Assembly 126028...

Page 17: ...Maintenance Maintenance 4 4 5 Figure 4 2 Primalert 35 Schematic 126015...

Page 18: ...Victoreen 05 437 Operators Manual 4 6 Figure 4 3 PC Assembly 126021...

Page 19: ......

Page 20: ...Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland Ohio 44139 440 498 2564 www flukebiomedical com rms...

Reviews: