2-28
VIBXPER
T II Balancing 12.2019
t
rigger
angle
: The angle between the sensor and the trigger sensor is
taken into account in the calculation of the attachment angle for
the trial weight. Convention: Angle is counted against the direction
of rotation of the rotor.
s
peeD
for
balance
quality
*
: Reference RPM for calculation of the
achieved balance grade and centrifugal force (see p.2-22).
c
heck
speeD
*:
Yes / No
; see "Check functions" on page 2-21.
c
ontrol
2
nD
plane
:
Yes / No
; when balancing in one plane, the vibra-
tion in a second plane can be recorded and displayed as well (see
also page 2-30).
M
iniMiZe
error
in
2
nD
plane
*
:
Yes / No
; generally, the vibration in the
control plane increases. Activate this option to calculate the balanc-
ing weights in such a way that the vibration in both the balancing
plane and the control plane are minimized.
a
uto
aVerage
:
Yes / No
; with a strongly varying imbalance pointer,
VIBXPERT automatically increases the selected number of averages
in the measurement setup. This option works only in combination
with the 'Check stability' option.
c
heck
stability
*:
Yes / No
; see "Check functions", p. 2-21.
c
heck
baD
influence
*:
Yes / No
; see "Check functions", p. 2-21.
r
ecalculating
coefficient
The coefficient for calculating the balancing weight can be taken
over from the trial run (setting: "No") or from the previous balanc-
ing run (setting: "Yes"). Only available for 1-plane balancing.
f
ree
-
run
:
Yes / No
; the free-run mode abbreviates the balancing pro-
cedure. In this mode, only the measurement screen appears. The
weight and the position of the balancing weights is not displayed.
In the machine setup, all options that are used to calculate the bal-
ancing weights are deactivated. This mode should only be used by
balancing experts.
Machine setup
* This parameter can be changed in
each balancing run (MENU - Tools)
Parameters in the machine setup
Left:
Machine setup for
2-plane balancing
Right:
Machine setup for
1-plane balancing