2-13
VIBXPER
T II Balancing 12.2019
1-plane balancing
4. Switch the machine on.
5. Press 'Enter' to start the measurement.
6. If the measurement values are stable, press 'Enter' to stop the mea-
surement.
7. Switch the machine off.
In the trial run the imbalance should change enough to steadily
reduce the residual imbalance in the subsequent balancing runs. If
the imbalance changes only slightly, increase the trial weight. If the
imbalance has more than doubled, use a smaller trial weight (see the
'Tools' parameter, 'Check bad influence', p. 2-21). If necessary, scroll
back in the data screen of the trial run, change the mass accordingly
and repeat the trial run.
Trim run
1. Press the right navigation key to close the measurement screen of
the trial run and to open the data screen of the first trim run.
Depending on whether the trial weight resulted in an improvement
or not, it can be left on the rotor or taken off. Respond to the result-
ing prompt in the screen accordingly.
2. Attach the recommended mass at the specified position on the ro-
tor. If necessary, also change the values.
3. Press the right navigation key until the next measurement screen
appears.
4. Switch the machine on.
5. Press 'Enter' to start the measurement.
6. If the measurement values are stable, press 'Enter' to stop the mea-
surement.
7. Switch the machine off.
Left:
Measure trial run
Right:
Trim run data screen
= Trial weight was removed