2-11
VIBXPER
T II Balancing 12.2019
1-plane balancing
Balancing in one plane
On the basis of an example, the next section illustrates the steps that
are needed to balance in one plane:
Requirements
- In the following example, the machine setup is not used.
- The default settings in the 'Tools' menu item are not changed:
- Correction mode: free
- "Add" balancing weights
- Check that the functions are all active, except for the coefficients
calculation which is inactive.
- 'Use different radii' option: inactive
Activating the balancing mode
1. Switch on VIBXPERT.
2. Click on the "Balancing" icon in the start screen.
Selecting the task
1. Open the '1-plane' tab.
2. Highlight the rotor graphic which corresponds to the rotor type.
3. Optional: Check and change the current measurement task before-
hand if necessary. (MENU - Task Manager - Setup)
4. Click on the rotor graphic to open the measurement screen
Adjusting the trigger sensor
1. Connect the trigger sensor to VIBXPERT (see p. 2-7).
2. Press MENU, and click on "Power up keyphasor".
3. Adjust the trigger sensor to the reference mark on the shaft.
Left:
Selection screen
Right:
Start 'Initial' run
Keyphasor ON