4-20
Display setup
C2. Display setup for trend: phase
Phase over...: When several phase measurements are saved in one
file, the phase vectors can be shown depending on the time or
rpm (see below).
Phase trend diagram
Use the F-key to open a menu in the results screen (see below) with
the following options:
Details:
Show result of a single measurement
Nyquist / Bode:
Change diagram type
Show channel:
Show channel A, channel B or both channels.
D. Display setup for measurement: 2-channel measurement (1+1)
Spectrum display:
If the measurement task contains a spectrum
measurement, you can choose whether only the
spectrum
,
or also the set
additional info
(max. 10, time waveform,.. see
section B1) should be displayed.
Display setup channel A / B: Click on
Show
to display the display
settings of the individual measurement tasks.
To edit the display settings of the individual measurement tasks,
enable the required window pane in the result screen and call
up the display setup via the MENU key (see diagram on page
5-24).
E. Display setup for measurement: impact test
Bump display: Choose whether the result of the impact test should
be displayed as a
time waveform
or
spectrum
.
Select result after save: The result selection dialog window opens
automatically (
yes
) after a measurement is stored.
Left:
Phase trend
Phase vector as a function
of the rpm (see figure) or the time
Right:
2-channel display setup for
1+1 measurement
Impact test