Fluke ULT800 User Manual Download Page 2

 

Warranty and Product Support 

Fluke Biomedical warrants this instrument against defects in materials and 
workmanship for one full year from the date of original purchase. During the 
warranty period, we will repair or, at our option, replace at no charge a prod-
uct that proves to be defective, provided you return the product, shipping 
prepaid, to Fluke Biomedical. This warranty does not apply if the product has 
been damaged by accident or misuse or as the result of service or modification 
by other than Fluke Biomedical. IN NO EVENT SHALL FLUKE BIO-
MEDICAL BE LIABLE FOR CONSEQUENTIAL DAMAGES. 
Only serialized products and their accessory items (those products and items 
bearing a distinct serial number tag) are covered under this one–year warranty. 
PHYSICAL DAMAGE CAUSED BY MISUSE OR PHYSICAL ABUSE IS 
NOT COVERED UNDER THE WARRANTY. Items such as cables and 
nonserialized modules are not covered under this warranty. 
Recalibration of instruments is not covered under the warranty. 
This warranty gives you specific legal rights, and you may also have other 
rights which vary from state to state, province to province, or country to 
country. This warranty is limited to repairing the instrument to Fluke Bio-
medical’s specifications. 

Warranty Disclaimer 

Should you elect to have your instrument serviced and/or calibrated by some-
one other than Fluke Biomedical, please be advised that the original warranty 
covering your product becomes void when the tamper-resistant Quality Seal is 
removed or broken without proper factory authorization. We strongly rec-
ommend, therefore, that you send your instrument to Fluke Biomedical for 
factory service and calibration, especially during the original warranty period. 
In all cases, breaking the tamper-resistant Quality Seal should be avoided at all 
cost, as this seal is the key to your original instrument warranty. In the event 
that the seal must be broken to gain internal access to the instrument, you 
must first contact Fluke Biomedical’s Technical Assistance Department at 
775-883-3400. You will be required to provide the serial number for your in-
strument as well as a valid reason for breaking the Quality Seal. You should 
break this seal only after you have received factory authorization. Do not 
break the Quality Seal before you have contacted us. Following these steps 
will help ensure that you will retain the original warranty on your instrument 
without interruption. 

 

Fluke Biomedical, 

6920 Seaway Blvd., Everett, WA 98203 USA 

 

Summary of Contents for ULT800

Page 1: ...ULT800 TEE Transducer Leakage Current Tester Users Guide PN 2461434 August 2005 2005 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companies...

Page 2: ...y This warranty is limited to repairing the instrument to Fluke Bio medical s specifications Warranty Disclaimer Should you elect to have your instrument serviced and or calibrated by some one other t...

Page 3: ...onductivity of the fluid A special dual element probe also connected to the ULT800 tests the conductivity of the fluid A green PASS light or a red FAIL light indicates the results of the conductivity...

Page 4: ...in their original condition and contact the carrier immediately to file a claim If the instrument is delivered in good physical condition but does not operate within specifications or if there are any...

Page 5: ...1 Every product returned to Fluke must have a Return Material Authorization RMA number To obtain an RMA contact Fluke through one of the following methods Phone 888 99FLUKE 888 993 5853 or 425 446 556...

Page 6: ...R LEAKAGE CURRENT TESTER INSTRUCTIONS 1 Connect the transducer and the adapters to the ULT 800 2 Press the ON TEST button and wait for the READY light 3 Select CONDUCTIVITY and press the ON TEST Butto...

Page 7: ...est or the Leakage Test fails Pulses red when the Leakage Test results in less than 20 A indicating a possible open circuit condition with invalid test results LOW BAT Flashes red to indicate that the...

Page 8: ...ments on a single battery Conductivity Limit to pass greater than 250 A 5 Leakage Limits to pass less than 100 A 5 and greater than 20 A 5 A Dimensions 6 5 x 3 7 x 1 5 in 17 x 19 x 4 cm Weight 12 oz 3...

Page 9: ...nd compares the results to an internal threshold The instrument displays the results as a PASS or FAIL indication It also performs an internal self calibration on each measurement cycle The ULT800 mak...

Page 10: ...LT 800 2 Press the ON TEST button and wait for the READY light 3 Select CONDUCTIVITY and press the ON TEST Button Wait for the PASS light 4 Select LEAKAGE and press the ON TEST button again observe PA...

Page 11: ...tton Wait for the PASS light 4 Select LEAKAGE and press the ON TEST button again observe PASS or FAIL light If test fails DO NOT USE TRANSDUCER Refer to the user s manual ON READY PASS FAIL LOW BAT TE...

Page 12: ...t remains on for 12 seconds The ULT800 then powers off to conserve the battery To resume testing power on the ULT800 allow the self check battery test to complete and then reinitiate the test 1 Select...

Page 13: ...ance Your ULT800 needs little maintenance or special care However treat it as a calibrated measuring instrument Avoid dropping or other mechanical abuse that could cause a shift in the calibrated sett...

Page 14: ...h the anti tamper case label broken is out of calibration A ULT800 that is out of calibration can cause excessive leakage current exposure to the patient risk of injury to the patient could result W C...

Page 15: ...cuson 156 series probes 2392453 600 202FG Ultrasound Transducer Adapter GE YMS RT 2392466 600 203FG Ultrasound Transducer Adapter GE CGR 2392475 600 204FG Ultrasound Transducer Adapter GE LogiQ 223160...

Page 16: ...s Acuson 260 series probes 2231811 600 360 Ultrasound Transducer Adapter Siemens Acuson 360 series probes 2392591 600 MPFG Ultrasound Transducer Adapter Siemens Acuson MP series probes 2392427 600 102...

Page 17: ...f electric shock Standby On P Manufacturer s declaration of product compliance with applicable EU directives LISTED 58GB E233218 UL Listing mark Do not mix with solid waste stream Dispose using a qual...