background image

8

TS22 Series Craft Test Sets
Users Guide

Storing Number in Repertory Memory (Auto 
Dialer)

The TS22 and TS22A Test Sets have 9 memory locations, 
which correspond to number keys 1 through 9. Each 
location will store up to 18 digits. If a nineteenth digit is 
entered, the previous digits will be cleared and the last 
digit (the nineteenth entered) starts a new string. If 
more than 18 digits are required, a second memory can 
be used.

Numbers can be placed in memory at any time. The test 
set may be either on-hook or off-hook, and does not 
need to be connected to the line. 

Storing a Number When On-Hook Or 
Disconnected (Preferred Method)

1

Press STO (STORE).

2

Press the number key for the desired memory 
location (1-9). This clears all extraneous digits from 
memory and will prepare the memory for storing 
a new number.

3

Enter the number to be stored.

Note

When either on-hook or off-hook, a number in 
memory can be lost if the “STO” (STORE) key 
and then a number key are accidentally pressed. 
The “#” key can not be stored when in the on-
hook mode. Use the off-hook mode method 
discussed below.

4

Press STO (STORE).

5

Press the number key for the chosen memory 
location (1-9).

Storing a Number You are Calling

1

Connect the test set to the line and receive dial 
tone.

2

Dial the number.

Note

In the Pulse mode, pressing STO will stop any 
further digits from being outpulsed, although 
all digits will be stored. Therefore, wait until all 
digits have been outpulsed before pressing 
STO.

3

Press the STORE/PROG key.

4

Press one of the number keys (0 through 9) to 
select the desired memory location.

Putting a Pause in a Stored Number

Note

Each time the PSE key is pressed, it counts as 
one dialing digit.

In some situations it may be necessary to put a pause 
between digits of a stored number, as when accessing a 
trunk through a PBX that requires a 9 to get an outside 
line. You can do this by pressing the PSE (PAUSE) key at 
the point where the pause is required. For example, to 
store the number 9-647-5430, with a pause between 
the 9 and 6, enter 9[PAUSE]6475430. When the 
number is dialed out, there will be a four-second pause 
between the 9 and 6. You can insert a longer pause by 
pressing PSE more than once.

Dialing a Stored Number

After receiving dial tone, press RCL (RECALL) and then 
the number key (1-9) for the memory location. For 
example, to dial a number stored in location 5, press 
RCL and then 5. The number will be automatically 
dialed.

Summary of Contents for TS 19

Page 1: ...TS 22 Series Craft Test Sets Users Guide PN 2451689 October 2005 2005 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies ...

Page 2: ...r or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB destination Fluke Net...

Page 3: ...ker Monitor Modes 5 Keypad Controls and Indicators 6 Operation 7 TS22 Amplified Speaker Mode 7 TS22A Speakerphone Mode 7 TS22A Speaker Monitor Mode 7 Selecting a Dial Signal 7 Last Number Redial 7 Storing Number in Repertory Memory Auto Dialer 8 Storing a Number When On Hook Or Disconnected Preferred Method 8 Storing a Number You are Calling 8 Putting a Pause in a Stored Number 8 Dialing a Stored ...

Page 4: ...TS22 Series Craft Test Sets Users Guide ii ...

Page 5: ...sonnel for line testing and temporary communications Specifications herein apply to TS22 and TS22A models unless otherwise noted Registration Registering your product with Fluke Networks gives you access to valuable information on product updates troubleshooting tips and other support services To register fill out the online registration form on the Fluke Networks website at www flukenetworks com ...

Page 6: ...he line cord the test set or both Increase separation between the source of the interference and the test set Try connecting to another working pair Physical Characteristics Housing See Figure 1 The housing for the TS22 Series Test Set is made of high impact polycarbonate which provides excellent insulating properties The test set is designed to provide rugged service and withstand the rough handl...

Page 7: ...set The TS22A speakerphone operates from line voltage in the TALK mode only When the speaker fails to operate at all operates intermittently or sounds distorted replace the 9 V battery with a similar battery See Replacing the Battery on page 9 for instructions on changing the battery Note If the test set fails to operate properly at any time first replace the battery and retest before sending the ...

Page 8: ... high Note When the speaker is on the polarity LEDs go out They will turn back on when the speaker timer elapses or is turned off via the SPEAKER button When the speaker is on the transmitter and receiver are automatically switched off to prevent acoustic feedback With no signal present the speaker will automatically turn off after 5 minutes to conserve battery power Any signal greater than a nomi...

Page 9: ...e regular transmitter and receiver to prevent acoustic feedback from the speaker The polarity LEDs turn off when the TS22A unit is switched from Talk mode to either the speakerphone mode or the speaker mode To prolong battery life the TS22A Test Set will automatically shut off the speakerphone or speaker after approximately five minutes when there has been no signal greater than 30 dBm Because of ...

Page 10: ...ulse modes PSE Key The PSE Pause key places a four second pause between numbers that are being entered into repertory memory The pause will take place when the stored numbers are redialed and is used to access second dial tone when dialing through a PBX Tone Pulse Switch In MONITOR mode this switch turns off the ringer In TALK mode this switch selects TONE or PULSE dialing mode Polarity Light Emit...

Page 11: ...the TALK MONITOR switch to M then press the SPEAKER button once to enter speaker mode with low volume 2 Press the SPEAKER button a second and third time for medium and high volume 3 Press the SPEAKER button a fourth time for off and return to Monitor mode Selecting a Dial Signal Select the type of dial signaling required DTMF or dial pulse with the TONE PULSE switch 1 Set the TALK MONITOR switch t...

Page 12: ...he number key for the chosen memory location 1 9 Storing a Number You are Calling 1 Connect the test set to the line and receive dial tone 2 Dial the number Note In the Pulse mode pressing STO will stop any further digits from being outpulsed although all digits will be stored Therefore wait until all digits have been outpulsed before pressing STO 3 Press the STORE PROG key 4 Press one of the numb...

Page 13: ...en circuit is accomplished by bridging the TS22 or TS22A Test Sets across the circuit one test lead on Tip the other on Ring Moving away from the CO the fault is located at the point the loud CLICK disappears 3 Continuity of each side of the loop may be verified by placing one of the line leads on a local ground and the other on the conductor in question On a good Ring conductor a CLICK will be he...

Page 14: ...um 9 V battery 7 Replace the battery boot retainer cover and screws Strain relief ring must be inside the case as shown Avoid pinching battery wires bfs06 eps Figure 5 Battery Replacement Replacing the Belt Clip See Figure 6 The belt clip assembly is field replaceable in the event of damage or prolonged wear To order a replacement belt clip contact your local Fluke Networks authorized distributor ...

Page 15: ...urce 9 V battery provides 25 hours continuous use typical Speaker Levels for TS22 Low medium high and off Automatic Power Shut Off After 5 min of no audio signal Speakerphone Levels TS22A Low medium high and off Power Source Shared line and battery power Physical Measurement 10 25 in x 2 69 in x 3 38 in 26 cm x 6 83 cm x 8 57 cm Weight TS22 21 ounces 595 kg TS22A 22 ounces 624 kg typical Environme...

Page 16: ...12 TS22 Series Craft Test Sets Users Guide ...