background image

7

Operation

Operation

TS22 Amplified Speaker Mode

To put the TS22 Test Set into amplified speaker mode:

1

Connect the test set to a line. The TALK/MONITOR 
switch may be in either position.

2

Press the SPEAKER button once to enter amplified 
speaker mode with low volume. 

3

Press the SPEAKER button a second and third time 
for medium and high volume. 

4

Press the SPEAKER button a fourth time to turn 
the amplified speaker off.

Pressing the MUTE button while in amplified speaker 
mode turns the speaker off.

TS22A Speakerphone Mode

To put the TS22A Test Set into speakerphone mode:

1

Connect the test set to a line. Set the TALK/
MONITOR switch to T.

2

Press the SPEAKER button once to enter 
speakerphone mode with low volume. 

3

Press the SPEAKER button a second and third time 
for medium and high volume. 

4

Press the SPEAKER button a fourth time to turn 
the speakerphone off and return to Talk mode.

Pressing the MUTE button while in speakerphone 
mode mutes the speakerphone microphone for 
privacy.

TS22A Speaker Monitor Mode

To put the TS22A Test Set into speaker monitor mode:

1

Set the TALK/MONITOR switch to M, then press 
the SPEAKER button once to enter speaker mode 
with low volume. 

2

Press the SPEAKER button a second and third time 
for medium and high volume. 

3

Press the SPEAKER button a fourth time for off 
and return to Monitor mode.

Selecting a Dial Signal

Select the type of dial signaling required, DTMF or dial 
pulse, with the TONE/PULSE switch:

1

Set the TALK/MONITOR switch to M.

2

Connect test set to the line; listen to verify that the 
line is idle.

3

Set the TALK/MONITOR switch to T, and verify that 
dial tone is received. 

4

Enter the number to be called. If DTMF signaling 
has been selected, the tones associated with each 
digit are generated as each key is pressed. If rotary 
dial pulse signaling has been selected, the number 
may be entered at any rate on the keypad; digits 
will automatically be pulsed out at the correct 
rate. 

To terminate the call, either during or after dialing, 
return the TALK/MONITOR switch to the M position.

Last Number Redial

Note

When dialing out through a PBX, you may use 
the PSE key to insert a pause before initially 
dialing the number. See “Putting a Pause in a 
Stored Number”.

In the Tone or Pulse mode, the last number dialed can 
be automatically redialed by pressing the LNR key after 
going on-hook and then back off-hook.

Summary of Contents for TS 19

Page 1: ...TS 22 Series Craft Test Sets Users Guide PN 2451689 October 2005 2005 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies ...

Page 2: ...r or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB destination Fluke Net...

Page 3: ...ker Monitor Modes 5 Keypad Controls and Indicators 6 Operation 7 TS22 Amplified Speaker Mode 7 TS22A Speakerphone Mode 7 TS22A Speaker Monitor Mode 7 Selecting a Dial Signal 7 Last Number Redial 7 Storing Number in Repertory Memory Auto Dialer 8 Storing a Number When On Hook Or Disconnected Preferred Method 8 Storing a Number You are Calling 8 Putting a Pause in a Stored Number 8 Dialing a Stored ...

Page 4: ...TS22 Series Craft Test Sets Users Guide ii ...

Page 5: ...sonnel for line testing and temporary communications Specifications herein apply to TS22 and TS22A models unless otherwise noted Registration Registering your product with Fluke Networks gives you access to valuable information on product updates troubleshooting tips and other support services To register fill out the online registration form on the Fluke Networks website at www flukenetworks com ...

Page 6: ...he line cord the test set or both Increase separation between the source of the interference and the test set Try connecting to another working pair Physical Characteristics Housing See Figure 1 The housing for the TS22 Series Test Set is made of high impact polycarbonate which provides excellent insulating properties The test set is designed to provide rugged service and withstand the rough handl...

Page 7: ...set The TS22A speakerphone operates from line voltage in the TALK mode only When the speaker fails to operate at all operates intermittently or sounds distorted replace the 9 V battery with a similar battery See Replacing the Battery on page 9 for instructions on changing the battery Note If the test set fails to operate properly at any time first replace the battery and retest before sending the ...

Page 8: ... high Note When the speaker is on the polarity LEDs go out They will turn back on when the speaker timer elapses or is turned off via the SPEAKER button When the speaker is on the transmitter and receiver are automatically switched off to prevent acoustic feedback With no signal present the speaker will automatically turn off after 5 minutes to conserve battery power Any signal greater than a nomi...

Page 9: ...e regular transmitter and receiver to prevent acoustic feedback from the speaker The polarity LEDs turn off when the TS22A unit is switched from Talk mode to either the speakerphone mode or the speaker mode To prolong battery life the TS22A Test Set will automatically shut off the speakerphone or speaker after approximately five minutes when there has been no signal greater than 30 dBm Because of ...

Page 10: ...ulse modes PSE Key The PSE Pause key places a four second pause between numbers that are being entered into repertory memory The pause will take place when the stored numbers are redialed and is used to access second dial tone when dialing through a PBX Tone Pulse Switch In MONITOR mode this switch turns off the ringer In TALK mode this switch selects TONE or PULSE dialing mode Polarity Light Emit...

Page 11: ...the TALK MONITOR switch to M then press the SPEAKER button once to enter speaker mode with low volume 2 Press the SPEAKER button a second and third time for medium and high volume 3 Press the SPEAKER button a fourth time for off and return to Monitor mode Selecting a Dial Signal Select the type of dial signaling required DTMF or dial pulse with the TONE PULSE switch 1 Set the TALK MONITOR switch t...

Page 12: ...he number key for the chosen memory location 1 9 Storing a Number You are Calling 1 Connect the test set to the line and receive dial tone 2 Dial the number Note In the Pulse mode pressing STO will stop any further digits from being outpulsed although all digits will be stored Therefore wait until all digits have been outpulsed before pressing STO 3 Press the STORE PROG key 4 Press one of the numb...

Page 13: ...en circuit is accomplished by bridging the TS22 or TS22A Test Sets across the circuit one test lead on Tip the other on Ring Moving away from the CO the fault is located at the point the loud CLICK disappears 3 Continuity of each side of the loop may be verified by placing one of the line leads on a local ground and the other on the conductor in question On a good Ring conductor a CLICK will be he...

Page 14: ...um 9 V battery 7 Replace the battery boot retainer cover and screws Strain relief ring must be inside the case as shown Avoid pinching battery wires bfs06 eps Figure 5 Battery Replacement Replacing the Belt Clip See Figure 6 The belt clip assembly is field replaceable in the event of damage or prolonged wear To order a replacement belt clip contact your local Fluke Networks authorized distributor ...

Page 15: ...urce 9 V battery provides 25 hours continuous use typical Speaker Levels for TS22 Low medium high and off Automatic Power Shut Off After 5 min of no audio signal Speakerphone Levels TS22A Low medium high and off Power Source Shared line and battery power Physical Measurement 10 25 in x 2 69 in x 3 38 in 26 cm x 6 83 cm x 8 57 cm Weight TS22 21 ounces 595 kg TS22A 22 ounces 624 kg typical Environme...

Page 16: ...12 TS22 Series Craft Test Sets Users Guide ...