background image

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke Networks product is warranted to be free from defects in material and workmanship under 
normal use and service. The warranty period for the mainframe is 18 months and begins on the date of 
purchase. Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. 
Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. The 
warranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, 
and does not apply to any product which, in Fluke Networks’ opinion, has been misused, abused, altered, 
neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke 
Networks warrants that software will operate substantially in accordance with its functional specifications 
for 90 days and that it has been properly recorded on non-defective media. Fluke Networks does not warrant 
that software will be error free or operate without interruption.

Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user 
customers only but have no authority to extend a greater or different warranty on behalf of Fluke Networks. 
Warranty support is available only if product is purchased through a Fluke Networks authorized sales outlet 
or Buyer has paid the applicable international price. Fluke Networks reserves the right to invoice Buyer for 
importation costs of repair/replacement parts when product purchased in one country is submitted for repair 
in another country.

Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price, 
free of charge repair, or replacement of a defective product which is returned to a Fluke Networks 
authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return 
authorization information, then send the product to that service center, with a description of the difficulty, 
postage and insurance prepaid (FOB destination). Fluke Networks assumes no risk for damage in transit. 
Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB destination). 
If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident 
or abnormal condition of operation or handling, or normal wear and tear of mechanical components, Fluke 
Networks will provide an estimate of repair costs and obtain authorization before commencing the work. 
Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be 
billed for the repair and return transportation charges (FOB Shipping point).

THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, 
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY 
CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or 
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other 
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any 
other provision.

4/04-18

Fluke Networks
PO Box 777
Everett, WA 98206-0777
USA

Summary of Contents for TS 19

Page 1: ...TS 22 Series Craft Test Sets Users Guide PN 2451689 October 2005 2005 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies ...

Page 2: ...r or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB destination Fluke Net...

Page 3: ...ker Monitor Modes 5 Keypad Controls and Indicators 6 Operation 7 TS22 Amplified Speaker Mode 7 TS22A Speakerphone Mode 7 TS22A Speaker Monitor Mode 7 Selecting a Dial Signal 7 Last Number Redial 7 Storing Number in Repertory Memory Auto Dialer 8 Storing a Number When On Hook Or Disconnected Preferred Method 8 Storing a Number You are Calling 8 Putting a Pause in a Stored Number 8 Dialing a Stored ...

Page 4: ...TS22 Series Craft Test Sets Users Guide ii ...

Page 5: ...sonnel for line testing and temporary communications Specifications herein apply to TS22 and TS22A models unless otherwise noted Registration Registering your product with Fluke Networks gives you access to valuable information on product updates troubleshooting tips and other support services To register fill out the online registration form on the Fluke Networks website at www flukenetworks com ...

Page 6: ...he line cord the test set or both Increase separation between the source of the interference and the test set Try connecting to another working pair Physical Characteristics Housing See Figure 1 The housing for the TS22 Series Test Set is made of high impact polycarbonate which provides excellent insulating properties The test set is designed to provide rugged service and withstand the rough handl...

Page 7: ...set The TS22A speakerphone operates from line voltage in the TALK mode only When the speaker fails to operate at all operates intermittently or sounds distorted replace the 9 V battery with a similar battery See Replacing the Battery on page 9 for instructions on changing the battery Note If the test set fails to operate properly at any time first replace the battery and retest before sending the ...

Page 8: ... high Note When the speaker is on the polarity LEDs go out They will turn back on when the speaker timer elapses or is turned off via the SPEAKER button When the speaker is on the transmitter and receiver are automatically switched off to prevent acoustic feedback With no signal present the speaker will automatically turn off after 5 minutes to conserve battery power Any signal greater than a nomi...

Page 9: ...e regular transmitter and receiver to prevent acoustic feedback from the speaker The polarity LEDs turn off when the TS22A unit is switched from Talk mode to either the speakerphone mode or the speaker mode To prolong battery life the TS22A Test Set will automatically shut off the speakerphone or speaker after approximately five minutes when there has been no signal greater than 30 dBm Because of ...

Page 10: ...ulse modes PSE Key The PSE Pause key places a four second pause between numbers that are being entered into repertory memory The pause will take place when the stored numbers are redialed and is used to access second dial tone when dialing through a PBX Tone Pulse Switch In MONITOR mode this switch turns off the ringer In TALK mode this switch selects TONE or PULSE dialing mode Polarity Light Emit...

Page 11: ...the TALK MONITOR switch to M then press the SPEAKER button once to enter speaker mode with low volume 2 Press the SPEAKER button a second and third time for medium and high volume 3 Press the SPEAKER button a fourth time for off and return to Monitor mode Selecting a Dial Signal Select the type of dial signaling required DTMF or dial pulse with the TONE PULSE switch 1 Set the TALK MONITOR switch t...

Page 12: ...he number key for the chosen memory location 1 9 Storing a Number You are Calling 1 Connect the test set to the line and receive dial tone 2 Dial the number Note In the Pulse mode pressing STO will stop any further digits from being outpulsed although all digits will be stored Therefore wait until all digits have been outpulsed before pressing STO 3 Press the STORE PROG key 4 Press one of the numb...

Page 13: ...en circuit is accomplished by bridging the TS22 or TS22A Test Sets across the circuit one test lead on Tip the other on Ring Moving away from the CO the fault is located at the point the loud CLICK disappears 3 Continuity of each side of the loop may be verified by placing one of the line leads on a local ground and the other on the conductor in question On a good Ring conductor a CLICK will be he...

Page 14: ...um 9 V battery 7 Replace the battery boot retainer cover and screws Strain relief ring must be inside the case as shown Avoid pinching battery wires bfs06 eps Figure 5 Battery Replacement Replacing the Belt Clip See Figure 6 The belt clip assembly is field replaceable in the event of damage or prolonged wear To order a replacement belt clip contact your local Fluke Networks authorized distributor ...

Page 15: ...urce 9 V battery provides 25 hours continuous use typical Speaker Levels for TS22 Low medium high and off Automatic Power Shut Off After 5 min of no audio signal Speakerphone Levels TS22A Low medium high and off Power Source Shared line and battery power Physical Measurement 10 25 in x 2 69 in x 3 38 in 26 cm x 6 83 cm x 8 57 cm Weight TS22 21 ounces 595 kg TS22A 22 ounces 624 kg typical Environme...

Page 16: ...12 TS22 Series Craft Test Sets Users Guide ...