Note
The adjusted dial gauge values conform to the validity rule. The displayed coupling res-
ults are not affected by the validation process.
Convert coupling results to dial gauge readings
From the measurement table, select measurement whose coupling results are to be converted
to dial gauge values.
Tap
then tap the option "Convert measurement to dial gauge".
Select the desired dial gauge set-up, then enter the axial (A) and radial (R) dimensions, and
the amount of bracket sag.
Tap
to view the fitting dial gauge values and the corresponding coupling results.
ROTALIGN touch EX
61
On-board help
Summary of Contents for PRUFTECHNIK ROTALIGN touchEX