P5514, P5514-V & P5514-EP
Users Manual
2
Operating Fluid Compatibility
The standard system is designed for use with a wide range of fluids; however, the O-ring
seals are Nitrile; use of solvents, fuel oils, brake fluids or other, similar aggressive fluids
can damage the seals. The table below details the two alternative versions of this
instrument, which offer increased compatibility with other fluids.
Table 1. Operating Fluid Compatibility
Model O
Rings
P5514 Nitrile
P5514-V Viton
P5514-EP Ethylene
Propylene
Rotate reservoir dust cover through ½ turn and fill reservoir approximately 3/4 full with
the appropriate fluid. Rotate dust cover back to cover reservoir.
W
Caution
To avoid damage to the instrument, the operator should check
the quality of the operating fluid during use. If the fluid
becomes discolored, cloudy or particles appear in the reservoir,
the system should be drained and flushed with clean fluid.
Safety Information
The following are general safety precautions that are not related to any specific
procedures and do not appear elsewhere in this publication. These are recommended
precautions that personnel must understand and apply during equipment operation and
maintenance to ensure safety and health and protection of property.
Compressed Liquid
Use of compressed liquids can create an environment of propelled foreign matter.
Pressure system safety precautions apply to all ranges of pressure. Care must be taken
during testing to ensure that all hydraulic connections are properly and tightly made prior
to applying pressure. Personnel must wear eye protection to prevent injury.
W
Warning
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.
Personal Protective Equipment
Wear eye protection approved for the materials and tools being used.
Symbols Used in this Manual
In this manual, a
Warning
identifies conditions and actions that pose a hazard to the
user. A
Caution
identifies conditions and actions that may damage the Hydraulic
Comparison Test Pump.
Symbols used on the Hydraulic Comparison Test Pump and in this manual are explained
in Table 2.