Integrated Network Analyzer
Specifications
51
Characteristic Impedance
50 to 150 Ohms, cables 3-5 m (10-16 ft.) +/- (5 Ohms +10%)
50 to 150 Ohms, cables >5 m (16 ft.) +/- (5 Ohms +5%)
Resolution:
1 Ohm
Receive Level
100 to 5000mVp-p, +/- 5%
Resolution:
10mV
Datalink Signal
500mVp-p to 4000mVp-p
Measuring Terminated Cables
Cable Test analyzes individual twisted-pairs of a cable that are terminated into
most equipment vendors’ Ethernet ports such as on a hub, switch or NIC.
All cable tests other than wiremap and office locator ID are operational in the
presence of datalink signal.
Fault Tolerance
The RJ-45 10/100BASE-T Ethernet connection on the analyzer is designed to
withstand a maximum of 100 volts.
GBIC Identification
Identifies and operates with the following GBIC module types per SFF Document
Number SFF-8053, Gigabit Interface Converter, Rev. 5.4: LX (1300nm), SX
(850nm).
WireView
TM
Compatibility
Detects combinations of shorts, opens, and connector miswires. Compatible with
wire mapper/office locators (officially called WireView
TM
, also called wire map
adapter and office locator) labeled for Fluke Networks OptiView
TM
analyzer.
Summary of Contents for OptiView II Series