OptiView
TM
Series II
Getting Started Guide
36
User Interface Events that will Terminate a Remote Session
The active TCP/IP session between the user interface software and the analyzer
can be severed under the following conditions:
•
If IP parameters are manually changed on the analyzer and
Apply
is selected in
the
Setup | TCP/IP
screen
•
If
Auto
Reconfigure on Network Change
is checked in the TCP/IP setup
screen and the analyzer patch cable is disconnected and reconnected to
another
jack
•
If the Ethernet link goes down due to temporary network outage
•
If
Rerun Auto Config
is selected in the TCP/IP setup screen
•
If the encryption is changed in the
Setup | Security
screen
•
If
Find Unused IP and Apply
is selected in the TCP/IP setup screen
•
If
Rerun Cable Test
is selected
•
If the Analyzer MAC address is changed in the
Setup | Ethernet
screen
•
If
Receive only, do not transmit frames
is selected in the
Setup | Ethernet
screen
In the previous conditions, the popup message
There are <n> user interfaces that
may lose connection to the remote OptiView Analyzer, proceed anyway?
With
both the
Yes
and
No
buttons displayed.
Setting Up the Analyzer Security
The
Setup | Security
screen provides analyzer security settings for packet capture,
remote access, and SNMP configuration.
Note
The
Setup | Ethernet
screen allows you to select
Receive only, do
not transmit frames
, which turns off the analyzer transmit capability,
thus putting it on the network in silent mode. Turning off the analyzer
transmit capability disables the device query for name resolving and
other active tests such as Ping.
The analyzer's MAC address can also be changed in the
Setup |
Ethernet
screen for testing switch forwarding tables or ARP caches.