27
Specifications
Auto turn off
Automatically turns off after 5 minutes if
no keys are pressed. Backlight turns off
first.
Memory for settings
and test results
Non-volatile memory. Saves the results
from up to 99 tests.
Factory calibration
interval
None
Reflectance
threshold
User-selectable from -24 dB to -62 dB
Loss threshold
User-selectable from 0.5 dB to 6.1 dB
Distance to the first
reflective open
2 m
Shortest distance to
an open APC
connection
15 m
Maximum distance
23 km (14.3 miles or 75,459 ft)
Distance accuracy
(0 m to 23,000 m or
0 ft to 7,549 ft)
±1 m for reflective incidents ±1 % of length
±3 m for non-reflective incidents ±1 % of
length
Testing speed
< 10 seconds typical
Connector
Removable/cleanable SC adapter, UPC
polish
Fiber types tested
9/125
μ
m singlemode
Bulkhead quality
If no fiber is attached or if the connector is
dirty, the troubleshooter displays 0 m or 0
ft.
Live fiber detection
Detects optical signals at 1310, 1490, and
1550, and 1625 nm and shows ACTIVE LINE
if a signal is there. Looks for a signal every 3
seconds after the first detection. +7 dBm
maximum input power.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176