Users Guide
4-28
3.
Enter the length of the first section (five digits maximum, with no
commas), using the same units of measure (feet or meters) selected for the
Language configuration, then press
L
.
4.
Press
G
to move the cursor to the Section 1
Gauge
field.
5.
Press
A
(
Edit
), press
F
or
H
for the desired gauge, then press
L
.
6.
Press
G
to move the cursor to the
Load Coil
field.
7.
Press
A
(
Edit
), and press
F
or
H
to select
Y
if a load coil terminates the
section or
N
if it does not. Then, press
L
.
8.
Press
G
to move the cursor to the
Strap Dist.
field.
9.
If the Section 1 length entered is the actual
known
distance to the strap,
press
F
or
H
to select
Y
. Otherwise select
N,
and press
L
.
10.
Press
G
to move the cursor to the Section 2
Length
field.
11.
Repeat Steps 2-7 until you enter information for all of the sections. When
you finish, press
M
to return to the
RFL
results screen.
Note
It is important to make sure that the last section that you enter
contains the strap position. If an “
Insufficient Length Entered
”
message is displayed when you press the
M
key to exit the Multi-
gauge Entry screen, it is because the sum of the entered lengths is
shorter than the Distance-to-Strap length measured by the tester. In
this situation, first verify that the entered
Length
and
Gauge
information is correct. If so, increase the length you entered for the
last section. This change does not affect the accuracy of the results
but allows agreement between the entries and measurements.
Summary of Contents for 990DSL
Page 4: ......
Page 12: ...990DSL Users Manual viii...
Page 26: ...990DSL Users Guide 1 12...
Page 64: ...990DSL Users Guide 3 26...
Page 138: ...990DSL Users Guide 4 74...
Page 202: ...990DSL Users Guide 6 20...
Page 220: ...990DSL Users Manual 8 6...
Page 222: ...990DSL Users Guide...
Page 232: ...990DSL Users Guide A 10...
Page 238: ...990DSL Users Guide B 6...
Page 242: ...990DSL Users Manual 4 Z Zero Leads utility 3 20...