![Fluke 810 Getting Started Download Page 8](http://html.mh-extra.com/html/fluke/810/810_getting-started_2310425008.webp)
810
Getting Started
2
Features
•
On-board diagnosis and location of the four most
common standard mechanical faults: bearings,
looseness, misalignment, unbalance and other (non-
standard faults)
•
Fault severity scale with four severity levels: Slight,
Moderate, Serious, and Extreme
•
Prioritized repair recommendations
•
Diagnostic details include cited peaks and vibration
spectra
•
Context Sensitive Help
•
2 GB expandable on-board memory
•
Data export (via USB connection) for more detailed
analysis
•
Self-test
•
Laser tachometer for accurate machine running speed
•
100 mV/g TEDS triaxial accelerometer
•
Data storage and tracking with included Viewer
Software
•
Color LCD display
•
Languages: English, French, German, Italian,
Portuguese, Spanish, Japanese, Simplified Chinese
Safety
The Tester complies with:
In this manual, a
Warning
identifies hazardous conditions
and actions that could cause bodily harm or death. A
Caution
identifies conditions and actions that could
damage the Tester, the equipment under test, or cause
permanent loss of data.
Warning
To avoid personal injury, follow these
guidelines for the Tester:
•
Use only as specified in this manual or
the protection provided by the Tester
might be impaired.
•
Do not use if damaged. Before you use
the Tester, inspect the case. Look for
cracks or missing plastic. Pay particular
attention to the insulation surrounding
the connectors.
•
Make sure the battery is securely in
place before operation.
•
Do not operate around explosive gas,
vapor, or dust.
•
Use proper protective equipment, as
required by local or national authorities,
when working in hazardous areas.