![Fluke 80i-110s Instructions Manual Download Page 8](http://html1.mh-extra.com/html/fluke/80i-110s/80i-110s_instructions-manual_2309087008.webp)
Battery
Type ......................................... 9 volt, IEC 6LR61
Consumption ............................ 8.6 mA typical
12 mA maximum
Service life with Alkaline IEC 6LR61 battery
Typical.............................. 55 hours
Minimum........................... 40 hours
Battery indicator (ON)............... Green LED dims when battery
voltage is <6.5 V
Safety
General..................................... IEC 61010-1: Pollution Degree 2
Measurement ........................... IEC 61010-2-032: CAT III 600 V
Electromagnetic Compatibility (EMC)
International.............................. IEC 61326-1: Portable
Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or use
conductively coupled radio-frequency energy which is necessary for
the internal functioning of the equipment itself.
Class A: Equipment is suitable for use in all establishments other
than domestic and those directly connected to a low voltage power
supply network which supplies buildings used for domestic purposes.
There may be potential difficulties in ensuring electromagnetic
compatibility in other environments, due to conducted and radiated
disturbances.
Caution: This equipment is not intended for use in residential
environments and may not provide adequate protection to radio
reception in such environments.
Emissions that exceed the levels required by CISPR 11 can occur
when the equipment is connected to a test object.
USA (FCC) ............................... 47 CFR 15 subpart B. This product is
considered an exempt device per
clause 15.103.
Electrical Specifications
Valid temperature ............................. 23 °C ±3 °C (73 °F ±5 °F).
Current Ranges ................................ 0 A dc to 10 A dc or ac peak
0 A dc to 100 A dc or ac peak
Output Signals.................................. 10 A range: 100 mV/A
100 A range: 10 mV/A
Basic Accuracy (DC to 1kHz):
Input Current
(DC or AC peak)
Error (after zero check)
Range 100 mV/A
Range 10 mV/A
0 A to 10 A
0 A to 40 A
40 A to 80 A
80 A to 100 A
<3 % of r50 mA
-
-
-
-
<4 % of r50 mA
<12 % of r50 mA
<15 % of reading