Specifications  

Operating Temperature ................... -20 

°

C to +50 

°

C  

Storage Temperature ...................... -20 

°

C to +70 

°

Operating Humidity.......................... 5 % to 95 % relative humidity, non-condensing 
Operating Altitude............................ <2000 m 
Pressure Range .............................. 0 MPa to 21 MPa (3000 psi) 

Adjustment Resolution .................... 0.05  % of reading  

Wetted Materials  

(700HPP) ..............................  Acetal, Aluminum, Brass, Silicone Loctite 577, Nitrile, Polypropylene, PTFE, Steel, 

Stainless Steel, Viton 

(700HPM) ............................. Aluminum, Stainless Steel, Nitrile, Urethane, PVC 

Leak Rate (700HPPK,  
with isolation valve closed) .............. 0.01  % reading  
Weight ............................................. 7257  g (16.0 lb) 

Dimensions ..................................... 740  x  295 x 155 mm  

 

(29.13 x 11.61 x 6.10 in) 

Safety: 

General ...................................... IEC 61010-1 

 

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty 

does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal 

conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain 

service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization 
information, then send the product to that Service Center with a description of the problem. 
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR 

PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR 

CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do 

not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability 

may not apply to you. 
 

Fluke Corporation 

P.O. Box 9090 

Everett, WA 98206-9090 

U.S.A. 

Fluke Europe B.V. 

P.O. Box 1186 

5602 BD Eindhoven 

The Netherlands 

11/99 

 

Summary of Contents for 700HPPK

Page 1: ...nder test Warning To prevent personal injury Read all safety information before you use the Product Use the Product only as specified or the protection supplied by the Product can be compromised Carefully read all instructions Do not use the Product if it operates incorrectly Do not use the Product if it is altered or damaged Disable the Product if it is damaged Do not attempt to operate the Produ...

Page 2: ...the Product after maintenance or repair 1 Wear eye protection and securely attach a pressure gauge to the hose or accessory fitting of the calibration manifold 700HPPK only Use any approved properly rated adapter as required 2 Close the upper vent valve 700HPPK and slowly pressurize the pump gauge system to 21 MPa 3000 psi 210 bar 3 Maintain pressure for 60 seconds 4 Use the upper vent valve on th...

Page 3: ...end of the hose to the device to be pressurized with the fittings provided 2 Make sure that the vent valve at the bottom of the Product is closed 3 Pump the Product to generate pressure For maximum efficiency use full pump strokes Generally 21 MPa 3000 psi can be generated within 20 seconds when full strokes are used for volumes of approximately 10 cm3 4 To vent the pressure use the vent valve on ...

Page 4: ...old slightly to drain all the liquid contaminants from inside that port 4 Clean the screen of any particulates or replace if necessary 5 Reinstall the screen and tighten the fitting Lubricate the Pump If generation of pressure becomes difficult due to friction in the pump then the pump may require lubrication Depending on usage lubrication of the pump may be required monthly Lack of lubrication ca...

Page 5: ...ere is a large black seal If it is worn replace it When you reassemble the pump add small amount of silicone grease to this seal 9 Remove the small diameter piston rod 10 On the bottom of the small diameter piston rod there is a small black seal If it is worn replace it The seal on top of the ball seal retainer nut should not need replacement 11 On the bottom of the piston there is a small green s...

Page 6: ...sable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a des...