background image

PN 4784850 

September 2016 
© 2016 Fluke Corporation, All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective 
companies.

 

 

700HPPK 

High Pressure Pneumatic Test Pump 

Instructions 

Introduction 

The Fluke 700HPP High Pressure Pneumatic Test Pump 

(the Product) is a portable device that produces precise 

pressures up to 21 MPa (3000 psi). The 700HPPK (the 

Kit) includes the Product and a High Pressure Calibration 
Manifold (HPM) with hose. 

Contact Fluke Calibration 

To contact Fluke Calibration, call one of the following 
telephone numbers: 

 

Technical Support USA: 1-877-355-3225 

 

Calibration/Repair USA: 1-877-355-3225 

 

Canada: 1-800-36-FLUKE (1-800-363-5853) 

 Europe: 

+31-40-2675-200 

 Japan: 

+81-3-6714-3114 

 Singapore: 

+65-6799-5566 

 China: 

+86-400-810-3435 

 Brazil: 

+55-11-3759-7600 

 

Anywhere in the world: +1-425-446-6110 

To see product information or download manuals and the 

latest manual supplements, visit Fluke Calibration’s 

website at

 www.flukecal.com.

 

To register your product, visit 

http://flukecal.com/register-

product.

 

Safety Information 

Warning

 identifies conditions and procedures that are 

dangerous to the user. A 

Caution

 identifies conditions and 

procedures that can cause damage to the Product or the 
equipment under test. 

Warning 

To prevent personal injury: 

 

Read all safety information before you use 
the Product. 

 

Use the Product only as specified, or the 
protection supplied by the Product can be 
compromised. 

 

Carefully read all instructions. 

 

Do not use the Product if it operates 
incorrectly. 

 

Do not use the Product if it is altered or 
damaged. 

 

Disable the Product if it is damaged. 

 

Do not attempt to operate the Product above 
its rated pressure. 

 

Avoid tipping the Product so that it will fall 
over. 

 

Use care when working with this Product. Do 
not drop the Product or strike it with sharp 
objects. 

 

Carefully follow the cleaning and 
decontamination instructions in the manual. 
Do not use unapproved solvents or cleaners 
on the product. 

Symbols 

The symbols shown in Table 1 are found in these 
instructions or on the Product. 

Table 1. Symbols 

Symbol Definition 

 

WARNING.RISK OF DANGER. 



Consult user documentation. 

 

Certified by CSA Group to North American safety 
standards. 

 

Conforms to European Union directives. 



Conforms to relevant Australian Safety and EMC 
standards. 

 

This product complies with the WEEE Directive 
marking requirements. The affixed label indicates 
that you must not discard this electrical/electronic 
product in domestic household waste. Product 
Category: With reference to the equipment types in 
the WEEE Directive Annex I, this product is classed 
as category 9 "Monitoring and Control 
Instrumentation" product. Do not dispose of this 
product as unsorted municipal waste. 

Summary of Contents for 700HPPK

Page 1: ...nder test Warning To prevent personal injury Read all safety information before you use the Product Use the Product only as specified or the protection supplied by the Product can be compromised Carefully read all instructions Do not use the Product if it operates incorrectly Do not use the Product if it is altered or damaged Disable the Product if it is damaged Do not attempt to operate the Produ...

Page 2: ...the Product after maintenance or repair 1 Wear eye protection and securely attach a pressure gauge to the hose or accessory fitting of the calibration manifold 700HPPK only Use any approved properly rated adapter as required 2 Close the upper vent valve 700HPPK and slowly pressurize the pump gauge system to 21 MPa 3000 psi 210 bar 3 Maintain pressure for 60 seconds 4 Use the upper vent valve on th...

Page 3: ...end of the hose to the device to be pressurized with the fittings provided 2 Make sure that the vent valve at the bottom of the Product is closed 3 Pump the Product to generate pressure For maximum efficiency use full pump strokes Generally 21 MPa 3000 psi can be generated within 20 seconds when full strokes are used for volumes of approximately 10 cm3 4 To vent the pressure use the vent valve on ...

Page 4: ...old slightly to drain all the liquid contaminants from inside that port 4 Clean the screen of any particulates or replace if necessary 5 Reinstall the screen and tighten the fitting Lubricate the Pump If generation of pressure becomes difficult due to friction in the pump then the pump may require lubrication Depending on usage lubrication of the pump may be required monthly Lack of lubrication ca...

Page 5: ...ere is a large black seal If it is worn replace it When you reassemble the pump add small amount of silicone grease to this seal 9 Remove the small diameter piston rod 10 On the bottom of the small diameter piston rod there is a small black seal If it is worn replace it The seal on top of the ball seal retainer nut should not need replacement 11 On the bottom of the piston there is a small green s...

Page 6: ...sable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a des...