Manual Supplement
635/633 Users
8
12/01
On page 2-15, make the following changes:
Section 2-25, add the following to the end of the paragraph:
To arm the span, first select the ARM loop code. Then, press the
SEND LOOP UP key to arm the span. To disarm the span, press
the SEND LOOP DOWN key.
Section 2-26, add the following to the end of the paragraph:
To loop up the HTU-R, select the HTU-R loop code (with the
span armed) and press the SEND LOOP UP key. To loop down
the HTU-R, select the HTU-R loop code (with the span armed)
and press the SEND LOOP DOWN key.
Section 2-27, add the following to the end of the paragraph:
To loop up the HTU-C, select the HTU-C loop code (with the
span armed) and press the SEND LOOP UP key. To loop down
the HTU-C, select the HTU-C loop code (with the span armed)
and press the SEND LOOP DOWN key.
Section 2-28, add the following to the end of the paragraph:
To loop up the first doubler (if provided), select the HRE1 loop
code (with the span armed) and press the SEND LOOP UP key.
To loop down the first doubler, select the HRE1 loop code (with
the span armed) and press the SEND LOOP DOWN key.
Section 2-29, add the following to the end of the paragraph:
To loop up the second doubler (if provided), select the HRE2
loop code (with the span armed) and press the SEND LOOP UP
key. To loop down the second doubler, select the HRE2 loop
code (with the span armed) and press the SEND LOOP DOWN
key.
Section 2-30, add the following to the end of the paragraph:
To loop the HRU (remote interface) from the central office,
select the NREM loop code and press the SEND LOOP UP key.
To loop down the HRU, select the NREM loop code and press
the SEND LOOP DOWN key.