![Fluke 52120A User Manual Download Page 59](http://html1.mh-extra.com/html/fluke/52120a/52120a_user-manual_2309151059.webp)
Remote Operations
Remote Commands
3
3-7
There are SCPI commands that control the Product when it is used for stand-alone
operation. There are also SCPI commands in the 6105A command set that control the
Product when it is controlled by a 6105A. The 6105A commands for the Product are in
the phase current control of the command tree. The branch is the EAMP (External
AMPlifier) branch.
Note
The OUTPut[:STATe] command is used to control output state.
SCPI Command Summary
Tables 3-3 is a list of SCPI commands implemented in the Product. Table 3-4 is a list of
6105A SCPI commands that control the Product when it is controlled by a 6105A.
Table 3-3. SCPI Commands
Command Description
SYStem
:VERsion?
:ERRor?
CHAin
:FITTed?
:IDN?
INPut
:TYPE(?)
OUTPut
[:STATe](?)
:TERMinal
:ROUTe(?)
[:SOURce]
:CURRent
:RANGe(?)
:LCOMp(?)
:COMPliance?
CALibration
:SECure
:PASSword
:EXIT
:ADJust?
:SAVE?
STATus
:OPER[:EVENt](?)
:ENABle(?)
CONDition?
:QUES[:EVENt](?)
:CONDition
:PRESent
Path to SCPI commands
Gets the SCPI version installed in the Product
Gets the earliest error in the error queue
Path the chain function
Gets number of units in chain
Gets instrument identification
Path to input type coimmands
Sets or gets input type selection
Path to output commands
Sets or gets the output state. Operate or standby
Path to output terminal commands
Sets or gets which output terminals are used
Path to source commands
Path to source current commands
Sets or gets the current range
Sets or gets the state of the LCOMP feature
Gets the percentage of compliance
Path to the calibration function
Path to calibration security function
Used to enter the password to enable calibration
Exits calibration mode
Sets a specified calibration variable and returns results
Saves the calibration adjustments to non-volatile memory
Path to the status function
Gets the Operation Event Register contents
Sets the Operation Event Register mask
Gets the Operation Condition Register contents
Gets Questionable Event Register contents
Sets the Questionable Event Register mask
Sets registers to a SCPI defined state
Summary of Contents for 52120A
Page 2: ......
Page 6: ...52120A Users Manual iv...
Page 8: ...52120A Users Manual vi...
Page 10: ...52120A Users Manual viii...
Page 12: ...52120A Users Manual 1 2...
Page 32: ...52120A Users Manual 1 22...
Page 34: ...52120A Operators Manual 2 2...
Page 52: ...52120A Operators Manual 2 20...
Page 54: ...52120A Users Manual 3 2...
Page 66: ...52120A Users Manual 3 14...
Page 68: ...52120A Users Manual 4 2...
Page 72: ...52120A Users Manual 5 2...