110 PLUS and 115
Users Manual
8
Rotary Switch Positions
Switch
Position
Measurement Function
Model
Automatically selects ac or dc volts based on the sensed input with a low impedance input.
110 PLUS
Hz (button)
AC voltage from 0.06 to 600 V.
110 PLUS, 115
Frequency from 5 Hz to 50 kHz.
115
DC voltage from 0.001 V to 600 V.
110 PLUS, 115
AC voltage from 6.0 to 600 mV, dc-coupled. DC voltage from 0.1 to 600 mV.
110 PLUS, 115
Ω
Ohms from 0.1
Ω
to 40 M
Ω
.
110 PLUS, 115
Continuity beeper turns on at
<
20
Ω
and turns off at
>
250
Ω
.
110 PLUS, 115
Diode Test. Displays OL above 2.0 V.
115
Farads from 1 nF to 9999
μ
F. 115
Hz (button)
AC current from 0.1 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off).
>
10.00 A display
flashes.
>
20 A,
OL
is displayed. DC-coupled.
Frequency from 45 Hz to 5 kHz.
115
DC current from 0.001 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off).
>
10.00 A display
flashes.
>
20 A,
OL
is displayed.
115