Multimeters
General
Specifications
23
General Specifications
Maximum voltage between any Terminal and Earth Ground: 600 V
Display (LCD) .............................................. 6000 counts, updates 3/sec
Battery Type ................................................ 2 AAA, NEDA 24A, IEC LR03
Battery Life .................................................. 200 hours minimum
Temperature
Operating .................................................. 0 °C to 40 °C
Storage ..................................................... -30 °C to 60 °C
Relative Humidity
Operating Humidity ................................... Non-condensing when <10°C
≤
90 % at 10 °C to 30 °C;
≤
75 % at 30 °C to 40 °C
Operating Humidity, 40 M
Ω
Range ...........
≤
80 % at 10 °C to 30 °C;
≤
70 % at 30 °C to 40 °C
Altitude
Operating .................................................. 2000 m
Storage ..................................................... 12,000 m
Temperature Coefficient ............................. 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs ............ 11A, 1000V Fast Fuse, Fluke specified part only
106 & 107
Users Manual
24
Size (HxWxL) ............................................... 142 mm x 69 mm x 28mm
Weight .......................................................... 200 g
IP Rating....................................................... IEC 60529: IP 40
Safety ........................................................... IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment ................... IEC 61326-1: Portable
Electromagnetic Compatibility .................. Applies to use the Korea only.
Class A Equipment
(Industrial Broadcasting & Communication
Equipment)
[1]
[1] This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take
notice of it. This equipment is intended for use in business environments and is not to be used in homes
.