05-443/05-444
Users Manual
4
Symbols
Table 1 shows the symbols used in this manual or on the Product.
Table 1. Symbols
Symbol Description
Risk of Danger. Important information. See Manual.
Hazardous voltage. Risk of electric shock.
AC (Alternating Current)
Protective conductor terminal
Conforms to European Union directives
This product complies with the WEEE Directive (2002/96/EC) marking
requirements. The affixed label indicates that you must not discard this
electrical/electronic product in domestic household waste. Product
Category: With reference to the equipment types in the WEEE Directive
Annex I, this product is classed as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose of this product as unsorted
municipal waste. Go to Fluke’s website for recycling information.
General Specifications
Detectors
.................................................................. Internal G-M detectors
Display
...................................................................... 4-digit LED display with 2 cm (0.8 in.) character height
Display Range
.......................................................... 000.0 to 9999
Display Units
............................................................ Can be made to display in: µR/hr, mR/hr, R/hr, µSv/h, mSv/h, Sv/h,
µrem/hr, mrem/hr, rem/hr, cpm, cps, and others
Linearity
.................................................................... Readings within 10 % of true value with detector connected
Operating Range:
05-443 and 05-443-2200
................................... 1 µSv/h to 10 mSv/h (0.1 mR/hr to 1 R/hr)
05-444
................................................................ 0.01 mSv/h to 100 mSv/h (1 mR/hr to 10 R/hr)
Response
.................................................................. Typically 3 seconds from 10 % to 90 % of final reading
Status (green light)
.................................................. Indicates the instrument is functioning properly
Low Alarm
................................................................. Indicated by a yellow light and slow beep (1 per second) audible tone
(can be set at any point from 0.0 to 9999)
High Alarm
................................................................ Indicated by a red light and a fast beep (4 per second) audible tone
(can be set at any point from 0.0 to 9999)
Note
Audible indicators can be configured as a single beep by dipswitch if
desired. Audio intensity is controlled by rotating the baffle on the
audio device.
DET Fail
..................................................................... Indicated by a red light and an audible tone greater than 68 dB at
2 m (6.1 ft) for conditions of detector overload, no count from
detector or instrument failure
Low Bat
..................................................................... Indicated by a yellow light, beginning when 2 hours of battery life
remain
Connector
................................................................. Series “C” (others available)
Calibration Controls
................................................ Accessible from the front of instrument (protective cover provided)