![Fluidwell F133-P Manual Download Page 31](http://html1.mh-extra.com/html/fluidwell/f133-p/f133-p_manual_2308947031.webp)
FW_F133P_v1702_02_EN
Page 31
Label information pulse input type
– F1xx-..-..-XI (inside and outside the enclosure)
Fig. 23: Label information - Intrinsically safe application (typical)
5.2.
TERMINAL CONNECTORS INTRINSICALLY SAFE APPLICATIONS
The unit is classified as group IIB/IIIC by default.
Classification of the unit as group IIC is only possible under the following conditions:
The indicator is either supplied by
the internal supply (option -PC);
the external supply connected to terminals 0 and 1 (option -PD);
the circuit supply connected to terminals 7 and 8 (option -AP);
The maximum values for any of those circuits are those as defined for group IIB/IIIC;
No other active external Intrinsically safe circuits may be connected to the indicator, with
exception of circuits connected to terminals 3 and 4 and/or terminals 5 and 6; the maximum
values for any of those circuits are those as defined for group IIB/IIIC.