FW_F115P_v1702_02_EN
Page 12
3.1.1.
SETUP MENU - SETTINGS
1
TOTAL - A
11
unit
L; m
3
; kg; lb; GAL; USGAL; bbl; no unit
12
decimals
0000000; 111111.1; 22222.22; 3333.333
13
K-Factor:
0.000010 - 9999999
14
decimals K-Factor
0 - 6
2
FLOW RATE - A
21
unit
mL; L; m
3
; mg; g; kg; ton; gal; bbl; lb; cf; rev; - - - - (no
unit); scf; nm
3
; nL; p
22
time
/sec; /min; /hour; /day
23
decimals
0000000; 111111.1; 22222.22; 3333.333
24
K-Factor
0.000010 - 9,999,999
25
decimals K-Factor
0 - 6
26
calculation
per 1 - 255 pulses
27
cut-off
0.1 - 999.9 seconds
3
TOTAL - B
31
K-Factor
0.000010 - 9999999
32
decimals K-Factor
0 - 6
4
FLOW RATE - B
41
K-Factor
0.000010 - 9999999
42
decimals K-Factor
0 - 6
5
DISPLAY
51
function
total; rate; all
52
show A-B
enable; disable
53
light
0% (off); 20%; 40%; 60%;- 80%; 100% (full brightness)
6
POWER MANAGEMENT
61
LCD new
fast; 1 sec; 3 sec; 15 sec; 30 sec; off
62
battery mode
operational; shelf
7
FLOWMETER
71
signal A
npn; npn-lp; reed; reed-lp; pnp; pnp-lp; namur; coil-hi;
coil-lo; 8-1 DC; 12 DC; 24 DC
72
signal B
npn; npn-lp; reed; reed-lp; pnp; pnp-lp; namur; coil-hi;
coil-lo; 8-1 DC; 12 DC; 24 DC
73
bi-directional
disable; enable
74
phase
90 deg
– 270 deg
75
count negative
disable; enable
76
k-factor
single; dual
77
calculate
add; differ
8
ANALOG
81
output
disable; enable
82
rate-min
-999999 - 9999999
83
rate-max
-999999 - 9999999
84
rate-sel
signed; absolute; rate-A; rate-B
85
cut-off
0.0
– 9.9%
86
tune-min
0
– 9999
87
tune-max
0
– 9999
88
filter
01
– 99
9
PULSE
91
mode
signed; not negative; separated
92
width
0.001
– 9
93
decimals
0000000; 111111.1; 22222.22; 3333.333
94
amount
0.001
– 9999999
A
COMMUNICATION
A1
speed
1200; 2400; 4800; 9600; 9600HP; 19200; 38400
A2
address
1
– 247
A3
mode
bus-rtu; bus-asc; off
A4
databits
8 bits; 7 bits
A5
parity
none; even; odd