Page 47
FW-F030-P-M_v0404_01_EN.docx
Sensor excitation
Type PB / PC / PX
Sensor supply voltage: 3.2V DC for low power pulse signals and 1.2V DC for coil pick-up.
Type PD
Sensor supply output 8.2V DC, max. 5mA (additional to type PX sensor excitation options).
Type PF / PM
sensor supply 8.2V, 12V and 24V DC - max. 400mA@24V DC (additional to type PX sensor
excitation options).
Terminal connections
Type:
Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2
Data protection
Type
EEPROM backup of all settings. Backup of running totals every minute.
Data retention at least 10 years.
Password
Configuration settings can be password protected.
Hazardous area (option)
Intrinsically safe
Type XI
ATEX approval: KEMA 05ATEX1168 X
II 1 G Ex ia IIC T4 Ga
II 1 D Ex ia IIIC T
200
100°C Da
CSA approval: CSA.08.2059461
IS Class I/II/III, Division 1, Groups A to G T4
Class I, Zone 0, AEx ia IIC T4 Ga
IECEx approval: IECEx KEM 08.0006X
Ex ia IIC T4 Ga
Ex ia IIIC T
200
100°C Da
FM approval: FM16US0177X
project ID: 3033306
IS Class I/II/III, Division 1, Groups A to G T4
Class I, Zone 0, AEx ia IIC T4 Ga
Explosion proof
Type XF
ATEX approval:
II 2 G Ex db IIB+H2 T5 Gb
II 2 D Ex tb IIIC T80°C Db
IECEx approval:
Ex db IIB+H2 T5 Gb
Ex tb IIIC T80°C Db
Weight
Dimensions
Appr. 15 kg.
350 x 250 x 200mm (13.7” x 9.9” x 7.9”) WxHxD.
Directives & Standards
EMC
EN 61326-1
FCC 47 CFR part 15
Low voltage
EN/IEC 61010-1
CSA C22.2 No. 61010-1
UL61010-1
ATEX
EN IEC 60079-0
EN 60079-11
IECEx
IEC 60079-0
IEC 60079-11
CSA c-us
CAN/CSA-C22.2 NO. 157
ANSI/UL 913
CAN/CSA-C22.2 NO. 142
UL 508
CAN/CSA-C22.2 NO. 60079-0
ANSI/ISA-60079-0
CAN/CSA-C22.2 NO. 60079-11 ANSI/ISA-60079-11
FM
FM Class 3600
ANSI/UL 60079-0
FM Class 3610
ANSI/UL 60079-11
FM Class 3810
RoHS
EN 50581
IEC 63000
IP & NEMA
EN 60529
ANSI/IEC 60529
NEMA 250
Note: See the applicable Declaration of Conformity or product certificate for specific revisions and publication dates.
Input
Flowmeter
Type P
Coil/sine wave (minimum 20mVpp or 80mVpp - sensitivity selectable), NPN/PNP, open
collector, reed-switch, Namur, active pulse signals.
Frequency Minimum 0 Hz - maximum 7 kHz for flow rate.
Maximum frequency depends on signal type and internal low-pass filter.
E.g. Reed switch with low-pass filter: max. frequency 120 Hz.
K-Factor 0.000010 - 9,999,999 with variable decimal position.
Low-pass filter Available for all pulse signals.
Type ZF
coil sensitivity 10mVpp.
Type ZG
coil sensitivity 5mVpp.
Output
Control output
Function
Batch process one stage control output
Type OA
One active 24V DC transistor output; max. 400mA per output (requires type PF or PM).
Type OR
One mechanic relay output; max. switch power 230V AC - 0,5A (requires type PF or PM).
Type OT
One passive transistor output - not isolated. Load max. 50V DC - 300mA.