User Manual
E115-P
Page 12
FW_E115-P_M_v0301-01_EN
CLEAR
-key
This key is used to clear the value of total.
The CLEAR-key also provides access to the LOG-mode, to review historical day totals.
Selecting displayed information
By pressing the SELECT-key, all relevant information can be reviewed on the display. When no key
is pressed for 20 seconds, the display will jump back to the main screen. The following image of the
display shows the main screen with Total shown on the top line and Flowrate on the bottom line.
Fig. 6:
Example of display information
The following table shows the available display information screens, determined by the configuration
settings for Display. If an operator alarm occurs, this will also be shown on the same screen – see
Section 4.5: Operator alarms [»14]
.
Display information
SETUP
= TOTAL
= FLOWRATE
= ACC. TOTAL
MAIN SCREEN
Total
1)
Flowrate
Flowrate
Total
1)
Acc. Total
SCREEN 1
Total
1)
Acc. Total
Total
1)
Acc. Total
Total
1)
Flowrate
SCREEN 2
2)
Current day Total
SCREEN 3
2)
Previous day Total
SCREEN 4
3)
Accumulated Total A
SCREEN 5
3)
Accumulated Total B
INTERNAL ERROR
4)
Internal alarm code
1)
When total is shown on the display, it can be cleared (reset to ‘0’) by pressing the CLEAR-key twice.
2)
Only available when day totals are enabled in
SETUP
5.2: DISPLAY > DAY TOTALS [»24]
3)
Only available when display of total A and B is enabled in
SETUP
5.3: DISPLAY > SHOW A-B (ACC. TOTAL) [»24]
.
4)
If an internal error occurs, an additional screen becomes available to show the internal alarm code.
Depending on
SETUP
6.4: FLOWMETER > CALCULATE [»27]
, the following information is shown in case of
reverse-flow:
● In ‘differential mode’, flowrate will be negative and total will count down, or
● In ‘not negative mode’, flowrate value will be zero and no totalization, or
● In ‘additive mode’ flowrate will be positive and total will count up.