5 MAINTENANCE
5.1
GENERAL DIRECTIONS
•
Mounting, electrical installation, start-up and maintenance of the instrument may only be
carried out by trained personnel authorized by the operator of the facility. Personnel must
read and understand this Operating Manual before carrying out its instructions. Take
careful notice of the “Safety rules, instructions and precautionary measures” in the front of
this manual.
•
The B-SMART may only be operated by personnel who are authorized and trained by the
operator of the facility. All instructions in this manual are to be observed.
•
Ensure that the measuring system is correctly wired up according to the wiring diagrams.
The housing may only be opened by trained personnel.
•
Take careful notice of the “Safety rules, instructions and precautionary measures” in the
front of this manual.
The B-SMART does not require special maintenance unless it is used in low-temperature
applications or surroundings with high humidity (above 90% annual mean). It is the users
responsibility to take all precautions to dehumidify the internal atmosphere of the B-SMART in such
a way that no condensation will occur, for example by placing dry silica-gel sachet in the casing just
before closing it. Furthermore, it is required to replace or dry the silica gel periodically as advised by
the silica gel supplier.
Battery life-time
The life-time of the battery is influenced by several issues:
•
Pulse output.
•
Analog output signal: be sure that an external power supply is connected or that the function is
disabled if not in use, as this has a major influence on the battery life-time.
•
Low temperatures; the available power will be less due to battery chemistry.
•
NPN and PNP inputs consume more energy than coil inputs.
•
High input frequency.
It is strongly advised to use only necessary functions.
Check periodically
•
The condition of the enclosure, cable glands and front panel.
•
The input/output wiring for reliability and aging symptoms.
•
The process accuracy. As a result of wear and tear, re-calibration of the flowmeter might be
necessary. Do not forget to re-enter any subsequent K-factor alterations.
•
The indication for low-battery. Replacement battery: see technical specifications.
•
Clean the enclosure with a lint-free cloth, soaked with a mild soap solution or fresh water.
5.2
INSTRUCTIONS FOR REPAIR
This product cannot be repaired by the user and must be replaced with an equivalent certified
product. Repairs are only allowed to be carried out by the manufacturer or his authorized agent.
Repair policy
If you have any problem with your product and you wish to have it repaired, please follow the
procedure below:
a. Obtain a Return Material Authorization (RMA) from your supplier or distributor. Together with the
RMA, you need to complete a repair form to submit detailed information about the problem.
b. Send the product, within 30 days, to the address provided with the RMA. The physical return of
your repair can only take place after the authorization of your repair application, as confirmed by
the RMA number.
If the product is within the warranty period and the reported problem falls under the warranty
conditions, the product will be repaired or exchanged and returned within three weeks. Otherwise,
you will receive a repair estimate.