5  MAINTENANCE 

5.1 

GENERAL DIRECTIONS 

 

  Mounting, electrical installation, start-up and maintenance of the instrument may only be 

carried out by trained personnel authorized by the operator of the facility. Personnel must 
read and understand this Operating Manual before carrying out its instructions. Take 
careful notice of the “Safety rules, instructions and precautionary measures” in the front of 
this manual. 

  The B-SMART may only be operated by personnel who are authorized and trained by the 

operator of the facility. All instructions in this manual are to be observed. 

  Ensure that the measuring system is correctly wired up according to the wiring diagrams. 

The housing may only be opened by trained personnel. 

 

Take careful notice of the “Safety rules, instructions and precautionary measures” in the 
front of this manual. 

 

The B-SMART does not require special maintenance unless it is used in low-temperature 
applications or surroundings with high humidity (above 90% annual mean). It is the users 
responsibility to take all precautions to dehumidify the internal atmosphere of the B-SMART in such 
a way that no condensation will occur, for example by placing dry silica-gel sachet in the casing just 
before closing it. Furthermore, it is required to replace or dry the silica gel periodically as advised by 
the silica gel supplier. 

 

Battery life-time 

The life-time of the battery is influenced by several issues: 

  Pulse output. 

  Analog output signal: be sure that an external power supply is connected or that the function is 

disabled if not in use, as this has a major influence on the battery life-time. 

  Low temperatures; the available power will be less due to battery chemistry. 

  NPN and PNP inputs consume more energy than coil inputs. 

  High input frequency. 

 

 

It is strongly advised to use only necessary functions. 

 

Check periodically 

  The condition of the enclosure, cable glands and front panel. 

  The input/output wiring for reliability and aging symptoms. 

  The process accuracy. As a result of wear and tear, re-calibration of the flowmeter might be 

necessary. Do not forget to re-enter any subsequent K-factor alterations. 

  The indication for low-battery. Replacement battery: see technical specifications. 

  Clean the enclosure with a lint-free cloth, soaked with a mild soap solution or fresh water. 

 

5.2 

INSTRUCTIONS FOR REPAIR 

This product cannot be repaired by the user and must be replaced with an equivalent certified 
product. Repairs are only allowed to be carried out by the manufacturer or his authorized agent. 

 

Repair policy 

If you have any problem with your product and you wish to have it repaired, please follow the 
procedure below: 

a.  Obtain a Return Material Authorization (RMA) from your supplier or distributor. Together with the 

RMA, you need to complete a repair form to submit detailed information about the problem. 

b.  Send the product, within 30 days, to the address provided with the RMA. The physical return of 

your repair can only take place after the authorization of your repair application, as confirmed by 
the RMA number. 

If the product is within the warranty period and the reported problem falls under the warranty 
conditions, the product will be repaired or exchanged and returned within three weeks. Otherwise, 
you will receive a repair estimate.

 

Summary of Contents for B-BASIC

Page 1: ...MART FLOWRATE INDICATOR TOTALIZER Signal input flowmeter pulse NAMUR and coil Signal outputs Analog referenced flowrate and scaled pulse referenced total B Series Basic indicators for ordinary locatio...

Page 2: ...e natural resources and ensure that it is recycled in a manner that protects the environment SAFETY RULES AND PRECAUTIONARY MEASURES The manufacturer accepts no responsibility whatsoever if the follow...

Page 3: ...connected instruments A caution indicates actions or procedures which if not performed correctly may lead to personal injury or incorrect functioning of the B SMART or connected instruments A note ind...

Page 4: ...Meter flowmeter 13 3 3 5 Menu 4 A OUT analog output 13 3 3 6 Menu 5 D OUT digital or pulse output 14 3 3 7 Menu 6 Other 14 4 INSTALLATION 15 4 1 General directions 15 4 2 Installation surrounding con...

Page 5: ...and aggravation Good readings in full sunlight and darkness through a bright backlight Mounting flexibility with a compact and durable IP65 enclosure for field wall or meter mounting Ability to proces...

Page 6: ...e implemented in many types of applications For that reason a SETUP level is available to configure your B SMART according to your specific requirements It includes several important features such as...

Page 7: ...Control panel Functions of the keys SELECT key This key is used to SELECT the displayed information like accumulated total and flowrate gain access to SETUP level please read chapter 3 CLEAR key This...

Page 8: ...p to 9 999 999 before rolling over to zero The unit and number of decimals are displayed according to the configuration settings for Total Clear total The value for Total can be cleared and reset to z...

Page 9: ...vice even when SETUP level is still active Make sure that the unit is not being used for any application when altering the settings 3 2 1 ENTERING SETUP LEVEL Configuration of the B SMART is done at S...

Page 10: ...ng new values alterations will only be set after the SELECT and CLEAR keys have been pressed simultaneously to confirm the new value STEP 3 Step 1 Starting the programming sequence SELECT CLEAR key Wh...

Page 11: ...4 7 4 Service port The Remote Configuration Tool software package can be downloaded from our website at www fluidwell com software and installed on a Microsoft Windows PC using the installation progr...

Page 12: ...curate the Total K Factor the more accurate the functioning of the system will be 1 4 K FACTOR DECIMALS This decimal point determines for K Factor SETUP 1 3 the number of digits following the decimal...

Page 13: ...it can be disabled to minimize power consumption to safe battery life When the output is disabled the current will be less than 3 4mA and the unit can still be supplied from this signal provided a po...

Page 14: ...utput is switched off Long represents a pulse length of 100ms max 5Hz Inter represents a pulse length of 15ms max 33Hz Short represents a pulse length of 5ms max 100Hz 5 2 DECIMALS The decimal point d...

Page 15: ...ck The housing may only be opened by trained personnel Take careful notice of the Safety rules instructions and precautionary measures at the front of this manual 4 2 INSTALLATION SURROUNDING CONDITIO...

Page 16: ...d on the outside of the unit Fig 6 Example external label with general data Installation label A second label is located on the inside and shows additional installation data Fig 7 Example internal lab...

Page 17: ...Page 17 FW_B SMART_v0306 01_EN docx 4 4 MECHANICAL INSTALLATION 4 4 1 DIMENSIONS ENCLOSURE Fig 8 Dimensions enclosure...

Page 18: ...er maximum 5mm 0 2 Shaft length minimum 50mm 2 Use the correct plugs if applicable Note The rear enclosure part can be rotated in steps of 90 enabling cable entry from any side Fig 9 Installation Wall...

Page 19: ...um rating of 0 5A e g fuse or circuit breaker must be inserted in the positive supply line in safe area The external power supply must be an approved ELV source insulated from AC mains by double reinf...

Page 20: ...e or sine wave coil The screen of the signal wire must be connected to the common ground terminal unless earthed at the sensor itself The sensor output of the flowmeter should match with the selected...

Page 21: ...ut Pulse signal PNP The B SMART is suitable for use with flowmeters which have a PNP output signal 3 0V is offered on terminal 3 which has to be switched by the sensor to terminal 2 SIGNAL For reliabl...

Page 22: ...sure the contact resistance of the reed switch is less than 10k Ohm Fig 15 Terminal connections Reed switch signal input NAMUR signal The B SMART is suitable for flowmeters with a NAMUR signal The B...

Page 23: ...ted from the internal electronics If the unit is only powered by the loop the backlight will not be activated Fig 17 Terminal connections 4 20mA analog output 4 7 3 TERMINAL 7 8 DIGITAL OUTPUT The fun...

Page 24: ...e g a laptop The port does not use the standard type connectors but the connections are made with a special service port communications cable which is available through your supplier or our website a...

Page 25: ...unction is disabled if not in use as this has a major influence on the battery life time Low temperatures the available power will be less due to battery chemistry NPN and PNP inputs consume more ener...

Page 26: ...ery with the utmost care to prevent a short circuit and damage 5 Do not recharge crush disassemble incinerate heat above its rated temperature or expose the contents to water 6 Dispose of the battery...

Page 27: ...consumption 25mA The power supply will also supply the backlight and the 8 2V DC sensor supply Battery Primary non rechargeable Lithium metal Thionyl Chloride Li SOCl2 1x3 6V 2 4Ah AA size IEC R6 ANS...

Page 28: ...eneral Transmitting flow rate Type Loop powered 4 20mA output not isolated Supply voltage 12V lift off voltage 30V DC Max load 600 Ohm 24V DC 24V 12V 20mA Accuracy 10 bit Error 0 5 20 C Typical 45ppm...

Page 29: ...tput does not function properly Check SETUP 4 1 is the function enabled SETUP 4 2 4 3 are the flow levels programmed correctly SETUP 4 4 4 5 are the 4mA and 20mA tuned correctly Connection of the exte...

Page 30: ...erlands luidwell is I certified by A ertification eander Arnhem he etherlands eghel ebruary 2022 We luidwell B declare under our sole responsibility that the B Series indicators are designed and will...

Page 31: ...technical specfication 27 terminal connectors 20 total accumulated 8 clear 8 decimals 12 display 8 K factor 12 K factor decimals 12 unit 12 LIST OF FIGURES Fig 1 Typical application for the B SMART 5...

Page 32: ...L coil 4 A OUT 4 1 OUTPUT disable 4 2 RATE MIN 4mA 0 L 4 3 RATE MAX 20mA 99999 L 4 4 TUNE MIN 4mA 1368 4 5 TUNE MAX 20mA 5466 5 D OUT 5 1 MODE Off 5 2 DECIMALS 0 5 3 AMOUNT 0 L 6 OTHERS 6 1 MODEL BASI...

Reviews: