Page 10
FW_B-SMART_v0306-01_EN.docx
Use the control panel to navigate the SETUP-menu
SELECT
-key
This key is used to select the next function in the list (e.g. 1
→
1.1
→
1.2
→
1). When
the top of the list is reached, it will wrap around and return to the function group
selection.
CLEAR
-key
This key is used to select the previous function in the list (e.g. 1.2
→
1.1
→
1
→
2).
When the bottom of the list is reached, it will return to the function group selection.
When only a function group is selected (and no function), this key is used to scroll to
the next function group. (e.g. 1
→
2
→
3
→
1).
3.2.3
CHANGING CONFIGURATION SETTINGS
After selecting a function in the SETUP-menu, a new value can be programmed using the control
panel. A function either contains a value (a number with optionally a decimal point, e.g. 123.45) or a
list with items (e.g. Disable
– Enable).
For each function that needs to change, navigate to that function and follow the steps indicated
below. During the programming sequence, the display will activate the
PROG
indicator.
When programming new values, alterations will only be set after the SELECT- and CLEAR-
keys have been pressed simultaneously to confirm the new value! (STEP 3)
Step 1: Starting the programming sequence
CLEAR
-key
When a function is selected at SETUP-level, press both keys simultaneously to
start the programming sequence.
Step 2a: Changing a value
SELECT
-key
This key is used to increment the selected digit or to select de next position of the
decimal point.
CLEAR
-key
This key is used to select the next digit or to select de previous position of the
decimal point.
Step 2b: Changing the selected item in a list
SELECT
-key
This key is used to select the next item in the list (e.g. Disable
→
Enable).
At the end of the list, the selection will wrap around to the first selection.
CLEAR
-key
This key is used to select the previous item in the list (e.g. Enable
→
Disable ).
At the bottom of the list, the selection will wrap around to the last selection.
Step 3: Finishing the programming sequence
CLEAR
-key
During the programming sequence, pressing both keys simultaneously is used to
confirm the new value and return to SETUP-level. To cancel the operation, wait
for 20 seconds: the programming sequence is cancelled and the former value is
reinstated.