R and RX SLURRY Pump USER INSTRUCTIONS ENGLISH
71569242 03-11 (E)
Page 25 of 56
flowserve.com
®
4.7.2 Maximum forces and moments allowed on M Slurry pump flanges
Flange Size
DN
(in.)
Maximum forces (F) in N (lbf) and moments (M) in Nm (lbf•ft)
Suction
Discharge
Mx
My
Mz
Fx
Fy
Fz
Mx
My
Mz
Fx
Fy
Fz
≤
50
≤
(2)
460
(340)
230
(170)
350
(260)
890
(200)
710
(160)
5808
(130)
460
(340)
230
(170)
350
(260)
710
(160)
580
(130)
890
(200)
65
(2-1/2)
710
(520)
350
(260)
540
(400)
1110
(250)
890
(200)
760
(170)
710
(520)
350
(260)
540
(400)
890
(200)
760
(170)
1110
(250)
80
(3)
950
(700)
470
(350)
720
(530)
1330
(300)
1070
(240)
890
(200)
950
(700)
470
(350)
720
(530)
1070
(240)
890
(200)
1330
(300)
100
(4)
1330
(980)
680
(500)
1000
(740)
1780
(400)
1420
(320)
1160
(260)
1330
(980)
680
(500)
1000
(740)
1420
(320)
1160
(260)
1780
(400)
125
(5)
1830
(1340)
940
(690)
1450
(1070)
2450
(550)
1960
(440)
1600
(360)
1830
(1340)
940
(690)
1450
(1070)
1960
(440)
1600
(360)
2450
(550)
150
(6)
2300
(1700)
1180
(870)
1760
(1300)
3110
(700)
2490
(560)
2050
(460)
2300
(1700)
1180
(870)
1780
(1300)
2490
(560)
2050
(460)
3110
(700)
200
(8)
3530
(2600)
1760
(1300)
2580
(1900)
4890
(1100)
3780
(850)
3110
(700)
3530
(2600)
1760
(1300)
2580
(1900)
3780
(850)
3110
(700)
4890
(1100)
250
(10)
5020
(3700)
2440
(1800)
3800
(2800)
6670
(1500)
5340
(1200)
4450
(1000)
5020
(3700)
2440
(1800)
3800
(2800)
5340
(1200)
4450
(1000)
6670
(1500)
300
(12)
6100
(4500)
2980
(2200)
4610
(3400)
8000
(1800)
6670
(1500)
5340
(1200)
6100
(4500)
2980
(2200)
4610
(3400)
6670
(1500)
5340
(1200)
8000
(1800)
350
(14)
6370
(4700)
3120
(2300)
4750
(3500)
8900
(2000)
7120
(1600)
5780
(1300)
6370
(4700)
3120
(2300)
4750
(3500)
7120
(1600)
5780
(1300)
8900
(2000)
400
(16)
7320
(5400)
3660
(2700)
5420
(4000)
10230
(2300)
8450
(1900)
6670
(1500)
7320
(5400)
3660
(2700)
5420
(4000)
8450
(1900)
6670
(1500)
10230
(2300)
450
(18)
8200
(6050)
4200
(3100)
6100
(4500)
11570
(2600)
9650
(2170)
7560
(1700)
8200
(6050)
4200
(3100)
6100
(4500)
9610
(2160)
7560
(1700)
11570
(2600)
500
(20)
9080
(6700)
4750
(3500)
6780
(5000)
12900
(2900)
10720
(2410)
8450
(1900)
9080
(6700)
4750
(3500)
6780
(5000)
10760
(2420)
8450
(1900)
12900
(2900)
550
(24)
10850
(8000)
5830
(4300)
8130
(6000)
15480
(3480)
13120
(2950)
10230
(2300)
10850
(8000)
5830
(4300)
8130
(6000)
13080
(2940)
10230
(2300)
15660
(3520)
Notes:
1) F = External force (tension or compression) M = External
moment, clockwise or counter-clockwise
2) Forces and moments may be applied simultaneously in any
direction
3) Values apply to all materials
4) Higher loads may be applicable, if direction and magnitude of
individual loads are known, but these need written approval from
Flowserve
5) Pumps must be on rigid foundations and baseplates must be
fully grouted
6) Pump/baseplate should not used as pipe anchor. Expansion
joints must be properly tied
7) The pump mounting bolt torques specified must be used to
prevent relative movement between the pump casing and
baseplate. (See section 6.6,
Fastener torques.
) The bolt
material must have a minimum yield strength of 600 N/mm
2
(87 000 lb/in.
2
)