8 Technical data
Ex- Characteristic (optional)
- Ex-marking
II 2G Ex ia IIC T4 Gb
TÜV 07 ATEX 553845
IECEx
Ex ia IIC T4 Gb
TUN 15.0038
If the sensor IPS Detect is to be installed in an explosion hazardous (Ex) area or other applications were
approvals are necessary, then respective official documentation must be observed. As standard, the unit can
be supplied with the following documentation: Operating Instruction, EC-Type Examination, Safety
Instruction and Declaration of Conformity)
Electrical Data
- output signal
4..20 mA with modulated FSK signal (physically Bell
202 HART
®
compatible)
only 8..20 mA support
IPS Detect:
10..20 mA vibration velocity
9 mA condition monitoring
- display sensor failure
21 mA (>20,5 mA)
- max. signal deviation
1,5 %
- min. current consumption
8 mA (4..8 mA are not supported)
- max. current consuption
22 mA
- min. required voltage at sensor input
11 V
- max. allowed load impedance
- connecting wire
2-wire
- connection 4-20 mA
Internal screw-clamping terminal
Environmental Condition
- Safety class at EN 60529
IP66
- Allowed ambient temperature
T
a
= -40 °C ... 80 °C
Mechanical Condition
- Dimension
76 x 40 x 53 mm
- Weight
0,12 kg
- Mounting of sensor
M8 screw
- Material of body
PA 6 GF 10 + GB 20, 22% Irgastadt P18, 3% colour
(
)
Summary of Contents for IPS Detect
Page 25: ...IPS Detect Page 25 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 26: ...IPS Detect Page 26 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 28: ...IPS Detect Page 28 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 30: ...IPS Detect Page 30 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 31: ...IPS Detect Page 31 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 32: ...IPS Detect Page 32 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...