IPS Detect
Page 10 of 35
OIM_FLS_IPS Detect_EN_14
Subject to technical changes!
FLOWSERVE
5
Operation IPS Detect
IPS Detect measures the
vibration velocity
of the pump in accordance with DIN/ISO
10816, 5199 and 9905 for preventive maintenance.
Furthermore, an optional
condition-monitoring
element can be simply activated in order
to monitor vibration up to 5.6kHz. For this condition monitoring to be possible, however,
the sensor must be calibrated beforehand (see topic 5.2). Subsequently, the sensor
compares actual values of the vibration Third-octave spectrum (up to 5.6 kHz) with pre-
defined alarm thresholds. Consequently, site personnel can be informed if these values
are exceeded.
5.1 Configuration
For most applications, the sensor is sent out already configured without the need to make
any changes. Should the user want to make any changes to the pre-set parameters,
however, then such configuration is possible with an FSK-modem (HART -Modem) with
the IPS Detect
EDD and DTM framework software tools or with IPS DataUSB
(SIHIdataUSB)
coupled to IPS Vibrosoft
software. See also page 30.
Picture: Configuration over IPS DataUSB (SIHIdataUSB) and IPS Vibrosoft Software
Summary of Contents for IPS Detect
Page 25: ...IPS Detect Page 25 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 26: ...IPS Detect Page 26 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 28: ...IPS Detect Page 28 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 30: ...IPS Detect Page 30 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 31: ...IPS Detect Page 31 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...
Page 32: ...IPS Detect Page 32 of 35 OIM_FLS_IPS Detect_EN_14 Subject to technical changes FLOWSERVE...